3.2.3 ParameterBox, SK TU3-PAR
This option is for simple parameterisation and control of the frequency
inverter, as well as the display of current operating settings and states.
Up to 5 data sets can be stored and managed, stored and transferred in
this device. This enables an efficient start-up for serial applications.
NOTE:
In order to be able to use the ParameterBox (external manual
control / switching cabinet unit) SK PAR-2H /-2E on the SK 5xxE,
this must at least be equipped with
software version
3.5 R1.
To ensure reliable operation the SK PAR-2H /-2E must be
connected to a stable 5V supply.
Features of the ParameterBox
•
Illuminated, high resolution LCD graphics screen
•
Large-screen display of individual operating parameters
•
6 language display
•
Help text for error diagnosis
•
5 complete inverter data sets can be stored in the memory, loaded and processed
•
For use as a display for various operating parameters
•
Standardisation of individual operating parameters to display specific system data
•
Direct control of a frequency inverter
Information from the ParameterBox
After lugging the ParameterBox onto the frequency inverter and switching on the mains for the first time, there
is initially an
enquiry as the menu language, German or English.
Then the ParameterBox automatically carried out a “
bus scan
”, during which the connected frequency
inverters are identified.
In the following display, the type of frequency inverter, its actual operating condition and the current status can
be seen.
After the inverter has been enabled, the display mode changes to the 3 current operate values (frequency,
voltage, current). The operating values displayed can be selected from a list of 19 possible values (in the
>Display< / > Values< menu).
NOTE
The digital frequency setpoint is factory set to 0Hz. To check whether the motor is working, a
frequency setpoint must be entered with the
key or a jog frequency via the respective
menu level >Parameterise<, >Base parameters< and the respective parameter >Jog
frequency< (P113)
Settings should only be implemented by qualified personnel, strictly in accordance with the
warning and safety information.
ATTENTION :
The motor may start immediately after pressing the START key
!