SETUP PROCEDURE
3-79
3.8.1
Confirmation of Gap Sensor/I-Mark Sensor
Feed 1 page of label and check the operation to see whether can detect the label.
As operations for Gap1 sensor, Gap2 sensor, I-Mark1 sensor, I-Mark2 sensor are all the same,
operation of “Gap1 Sensor” is selected as an example for explanation.
1
Under Sensor Check mode, turn
the dial to display “GAP1
SENSOR”.
2
Press the
key.
Feed 1 page of label to check the operation
as to whether label can be detected or not.
After checking, results will be displayed on
the LCD.
Results
Content
OK
Label detection successful. Sensor works properly.
NG
Label detection failure. There might be some abnormality.
3
Press the
key.
Return to selection of setting menu.
Press the
key
to return to selection of
setting mode.