Related tasks
You can configure network links for the ports used to connect the appliance to the Grid Network,
the Client Network, and the Admin Network. You can set the link speed as well as the port and
network bond modes.
Changing the MTU setting
You can change the MTU setting that you assigned when you configured IP addresses for the
appliance node.
Before you begin
•
You must have the Maintenance or Root Access permission. For details, see the instructions for
administering StorageGRID.
•
You must be signed in to the Grid Manager using a supported browser.
About this task
Before changing the MTU setting, you must place the SG1000 into maintenance mode. Putting a
StorageGRID appliance into maintenance mode might make the appliance unavailable for remote
access.
Steps
1. Follow these steps to place the appliance into maintenance mode:
a. From the Grid Manager, select Nodes.
b. From the tree view of the Nodes page, select the appliance Storage Node.
c. Select the Tasks tab.
d. Click Maintenance Mode.
A confirmation dialog box appears.
Hardware Installation and Maintenance Guide for SG5700 Appliances
84
Maintaining the SG5700 appliance