63
63
63
63
63
NESS D16 (V4.6) CONTROL PANEL - INSTALLER MANUAL
P101E - P116E
P88E
P89E
P96E
P97E
P98E
P99E
P91E
P94E
P95E
P90E
P118E
P119E
P117E
P87E
P85E
P86E
P83E
P84E
OPTION
DESCRIPTION
DEFAULT
PAGE
OPTION
DESCRIPTION
DEFAULT PAGE
OPTION
DESCRIPTION
DEFAULT
PAGE
Follow Me Tel. No.
none
1E Monitor to RESET OP
OFF
28
Test Call Interval
84=168hrs
RadioKey Enable Codes 1-8 none
2E Monitor to STROBE OP
OFF
Time before next Test Call 6=12 hours
RadioKey Enable Codes 9-15 none
3E Monitor to SONALERT
OFF
1E Auto Dialling, Pulse & DTMF
ON
44
User Code 1 (Master)
123
4E Monitor to SIREN
OFF
2E Pulse Dialling always
OFF
User Codes 2-15
none
5E Day Mode to RESET OP
ON
3E DTMF Dialling always
OFF
Entry Delay Time 1
20 sec
6E Day Mode to STROBE OP
ON
1E Disable Dialler
OFF
45, 46
47
48, 49
50, 51
52, 53
Entry Delay Time 2
6=60 sec
7E Day Mode to SONALERT
OFF
2E Contact ID format
ON
Exit Delay Time
60 sec
8E Day Mode to SIREN
OFF
3E Audible DTMF format
OFF
Siren Reset Time
5 min
1E Brief Monitor Alarm
OFF
OFF
29, 30
31
4E Audible PULSE Format
OFF
Normal Zone Sens
all zones
2E Brief Day Alarm
5E Contact ID + Audible DTMF
OFF
Vibration Sens. Z1-8
none
3E Monitor Zones Entry Delay2
ON
6E Contact ID + Audible PULSE
OFF
DoubleTrigger Zones
none
4E Radio Key Chirp & Flash
OFF
1E Split Dial Pri/Sec Phone Nos. OFF
Instant Zones
Zones 3-16
5E 50Hz Mains Frequency
ON
2E Check for Dial Tone
ON
Entry Delay 1 Zones
Zone 1
6E Double Key Keypad Panic
ON
4E 4 Dialling attempts
ON
Handover Zones
Zone 2
7E Keypad Fire Alarm
OFF
1E
AREA 1 Open/Close reports
OFF
Entry Delay 2 Zones
none
8E Keypad Medical Alarm
OFF
2E AREA 2 Open/Close reports
OFF
Lockout Zones
All zones
Supervised Radio Zones
none
3E Siren Chirp on Kiss-off
OFF
AREA 1 Zones
All zones
1E Supervision RESET output
OFF
32, 33
31
35
36, 37
38, 39
40
40
40
40
42, 43
4E Flash Strobe on Kiss-off
OFF
AREA 2 Zones
none
2E Supervision STROBE output
OFF
5E Forced Opening report
ON
AREA1 Codes 1-8
All codes
3E Supervision SONALERT
OFF
6E Delayed Closing Reports
OFF
AREA1 Codes 9-15
All codes
4E Supervision SIREN output
OFF
7E Manual Exclude Reports
ON
AREA2 Codes 1-8
Code 1
5E Supervision AUX1 output
OFF
8E Auto Exclude Reports
ON
AREA2 Codes 9-15
none
6E Supervision AUX2 output
OFF
1E Enable Test Calls
ON
Monitor Mode Zones
none
7E Supervision SpeedUp x 6
OFF
2E Mains Report Delay
ON
24hr Zones
none
8E Supervision SpeedUp x10
OFF
3E Listen-In to Dialler
OFF
Day Zones
none
Supervision Time
24 hours
4E Swinger shutdown
ON
Reset OP Zones
All zones
1E
ZONE SPLIT
OFF
5E Line Fault Monitor
OFF
Strobe Zones
All zones
2E 3K3 Zone Resistors
OFF
6E
7E
Line Fault to AUX2
Internal clock timing
OFF
OFF
Sonalert Zones
All zones
3E Radio Panic Toggles AUX1
OFF
1E Enable Up/Download
OFF
Siren Zones
All zones
4E Radio Panic Pulses AUX1
OFF
2E Enable Direct Connect
OFF
Aux 1 Zones
none
5E Radio Arm unseal warning
OFF
3E Enable Remote Arming
OFF
Aux 2 Zones
none
6E 24hr Zone Fire Siren
OFF
4E Enable Remote Disarming
OFF
1E Entry Beeps
ON
7E RK4 AUX button to AUX1
OFF
5E Enable Remote AUX control
OFF
2E Ksw Monitor/Disarm
OFF
8E Quiet chirps on Arm/Disarm OFF
6E Enable Remote Status report
OFF
3E Ksw Arm/Disarm
OFF
1E ARM1 Pulse Output
OFF
7E Enable Remote Event Report
OFF
4E Tamper siren lockout
ON
2E ARM2 Pulse Output
OFF
8E Enable Callback Mode
OFF
5E Duress to Reset OP
OFF
3E Quiet Monitor Siren
OFF
Required rings to answer
"No Memory Warning" zones
1
none
54
54
55
6E Auto Exclude Zones
ON
4E 6 Beeps on Arming
OFF
Clear Radio Devices
7E Auto KP display off
OFF
5E
6E
7E
8E
Radio Key Monitor Arm
Disable Mains fail alarm
RK4 AUX button toggles AUX2
RK4 AUX button pulses AUX2
OFF
OFF
OFF
OFF
Clear Memory
8E Delay Arm1,2 outputs
OFF
Factory Defaults
1E Tamper to Reset OP
ON
Telephone No.1 Primary
none
Clear User codes
2E Tamper to Strobe OP
ON
Telephone No.2 Secondary
none
Set Installer code
000000
14
57
60, 61
3E Tamper to Sonalert
ON
Account No. 1
0000
4E Tamper to Siren
ON
Account No. 2
0000
5E KP Panic to Reset OP
ON
Report Zone Alarms
All zones
1E Enable Output Expander
OFF
6E KP Panic to Strobe Op
ON
Report Misc. Alarms
2E Alternate Expander Format
OFF
7E KP Panic to Sonalert
ON
Report Zone Restorals
All zones
3E Day Zone Follower
OFF
8E KP Panic to Siren
ON
Report Misc. Restorals
4E Output Exclude
OFF
1E S/cut Memory display
ON
27, 28
26
24, 25
23
23
23
22
22
22
19
19
19
21
21
21
21
20
20
18
18
18
17
17
17
16
16
15
15
15
15
14
14
56
56
41
Report Multiple Zone alarms
none
42
42
41
41
43
Output Expander zone Follower none
2E S/cut Zone Exclude
ON
Account No.2 Zones
none
Output Expander zone Latch
none
3E S/cut Monitor Mode
ON
Tel No. 3 for Test Calls
none
4E S/cut Keypad Panic
OFF
Tel No.4 Callback
none
5E S/cut Area 1 Arm
ON
1E Restoral immediately
OFF
6E S/cut Area 2 Arm
OFF
2E Restoral after Siren Time
OFF
7E Auto Exclude 2s Warn
ON
3E Restoral on Disarm & seal
OFF
8E Exit Time x 10
OFF
4E Restore on Disarm always
ON
Radio Device Codes 1-16 none
P70E
P71E
P12E-P25E
P10E
P69E
P65E
P67
P82E
P60E
P27E
P28E
P29E
P30E
P31E-38E
P39E
P61E
P62E
P63E
P64E
P66E
P68E
P00E
P09E
P11E
P26E
P40E
P41E
P42E
P43E
P44E
P45E
P46E
P47E
P48E
P49E
P50E
P51E
P52E
P53E
P54E
P55E
P56E
P57E
P58E
P59E
P72E
P73E
P74E
P75E
P76E
P77E
P78E
P79E
P80E
P81E
These options are available in
.
USER PROGRAM MODE
ALL options are available in
INSTALLER PROGRAM MODE.
PROGRAMMING OPTIONS SUMMARY
Technical Manuals Online! - http://www.tech-man.com