P R O G R A M M I N G
NESS D16 (V4.6) CONTROL PANEL - INSTALLER MANUAL
P57E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
all ON: All zones trigger Siren output
NOTES:
•
0E
will turn all selections OFF
MEMORY E
will turn all selections ON
SIREN OUTPUT ZONES
Selects the zones to trigger the Siren output.
PROGRAMMING SEQUENCE:
P57E [Zone No]E
toggles the options ON and OFF
P57E [Zone No]E OFF: The zone will not trigger the Siren output
P57E [Zone No]E ON: The zone will trigger the Siren output
P58E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
all OFF: No zones trigger AUX1
NOTES:
•
0E
will turn all selections OFF
MEMORY E
will turn all selections ON
AUX1 OUTPUT ZONES
Selects the zones to trigger the AUX1 output. AUX1 output is Pin1 on the J3
header on the main board.
Once turned on by a zone alarm, the output will remain on until the panel is
reset/disarmed.
PROGRAMMING SEQUENCE:
P58E [Zone No]E
toggles the options ON and OFF
P58E [Zone No]E OFF: The zone will not trigger the AUX1 output
P58E [Zone No]E ON: The zone will trigger the AUX1 output
P59E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
all OFF: No zones trigger AUX2
NOTES:
•
0E
will turn all selections OFF
MEMORY E
will turn all selections ON
AUX2 OUTPUT ZONES
Selects the zones to trigger the AUX2 output. AUX2 output is Pin2 on the J3
header on the main board.
Once turned on by a zone alarm, the output will remain on until the panel is
reset/disarmed.
PROGRAMMING SEQUENCE:
P59E [Zone No]E
toggles the options ON and OFF
P59E [Zone No]E OFF: The zone will not trigger the AUX2 output
P59E [Zone No]E ON: The zone will trigger the AUX2 output