32
32
32
32
32
P R O G R A M M I N G
NESS D16 (V4.6) CONTROL PANEL - INSTALLER MANUAL
RADIO SUPERVISION ALERTS -
RESET OUTPUT
Setting this option turns the Reset output ON when a SUPERVISED RADIO alert
occurs. The Reset output will remain ON for the duration of the ALARM TIME
(Set by Option P29E).
PROGRAMMING SEQUENCE:
P66E 1E
toggles the option ON and OFF
P66E 1E OFF: Supervision Reset output disabled
P66E 1E ON: Supervision Reset output enabled
P66E 1E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: Supervis
ion
Reset output disabled
NOTES:
• RELATED OPTIONS:
P65E
Supervised Radio Zones
RADIO SUPERVISION ALERTS -
STROBE OUTPUT
Setting this option turns the Strobe output ON when a SUPERVISED RADIO
alert occurs. The Strobe output will remain ON until the panel is disarmed.
PROGRAMMING SEQUENCE:
P66E
2E
toggles the option ON and OFF
P66E 2E OFF: Supervision Strobe output disabled
P66E 2E ON: Supervision Strobe output enabled
P66E 2E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: Supervision Strobe output disabled
NOTES:
• RELATED OPTIONS:
P65E
Supervised Radio Zones
RADIO SUPERVISION ALERTS -
KEYPAD SONALERT & DELAY
ALL SUPERVISION OUTPUTS
Setting this option turns the Keypad Sonalert ON when a SUPERVISED RADIO
alert occurs. The Keypad Sonalert remains ON until
any
keypad key is pressed.
Also, turning this option ON makes all Supervision outputs delayed by one
minute.
PROGRAMMING SEQUENCE:
P66E 3E
toggles the option ON and OFF
P66E 3E OFF: Supervision Keypad Sonalert disabled
AND all Supervision outputs trigger instantly
P66E 3E ON: Supervision Keypad Sonalert enabled
AND all Supervision outputs are delayed by 1 minute
P66E 3E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: Supervision Keypad Sonalert disabled
NOTES:
• When this option is turned ON, it delays
the operation of all other selected
Supervision outputs by one minute.
• RELATED OPTIONS:
P65E
Supervised Radio Zones
1E 2E 3E 4E 5E 6E 7E 8E
ON = Factory default setting.
Super
vision RESET output
Super
vis
STROBE output
ion
Super
vis
SONALER
T outpu
t
ion
Super
vis
SIREN output
ion
Super
vis
A
UX1 output
ion
Super
vis
A
UX2 output
ion
Super
vis
speedup x6
ion
Super
vis
speedup x10
ion
OPTION No
DESCRIPTION
P66E
Radio Supervision Alerts
Technical Manuals Online! - http://www.tech-man.com