P R O G R A M M I N G
NESS D16 (V4.6) CONTROL PANEL - INSTALLER MANUAL
1E 2E 3E 4E 5E 6E 7E 8E
ON = Factory default setting.
Upload/DownloadDirect Connect R
emote Ar
ming
R
emote Disar
ming
R
emote A
UX control
R
emote Status repor
ting
R
emote Event repor
ting
Callback mode
OPTION No
DESCRIPTION
P90E
Upload/Download options
REMOTE ACCESS
When selected On, this option allows the panel to be remotely upload/
downloaded by a remote computer or controlled by a remote telephone.
When the option is Off, the panel will not answer incoming telephone calls,
preventing any type of remote access.
PROGRAMMING SEQUENCE:
P90E 1E
toggles the option ON and OFF
P90E 1E OFF: No Remote Access
P90E 1E ON:
Remote Access enabled
P90E 1E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: No Remote Access
NOTES:
• RELATED OPTIONS:
P91E
Required Rings
DIRECT CONNECT
This allows a direct connection to be used between the D16 telephone output
and an on site computer with modem.
Direct Connect simulates a telephone line ring and makes the D16 connect
immediately to the telephone line.
SEQUENCE:
• The panel must be in Installer Program mode.
• Dial the panel using NessComms™.
• While NessComms is ringing the panel, press P90E 2E.
• This forces the panel to pick up the line and comms can start.
P90E 2E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: No Direct Connect
NOTES:
• Remote Access must also be enabled
• RELATED OPTIONS:
P90E 1E
Enable Upload/Download
REMOTE ARMING
Allows the remote Arming of the control panel using a standard DTMF
telephone (or mobile phone) from anywhere in the world.
PROGRAMMING SEQUENCE:
P90E 3E
toggles the option ON and OFF
P90E 3E OFF: No Remote Arming
P90E 3E ON:
Remote Arming enabled
P90E 3E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: No Remote Arming
NOTES:
• Remote Access must also be enabled
• RELATED OPTIONS:
P90E 1E
Enable Upload/Download
• See page 62 for details on Remote
Operation by telephone
MODEM
12V BATTERY
6
2
270R
+
6
2
605
Plug
605
Plug
D16 Control Panel
COMPUTER
DIRECT CONNECT Diagram
Upload/download on site