27
27
27
27
27
P R O G R A M M I N G
NESS D16 (V4.6) CONTROL PANEL - INSTALLER MANUAL
SYSTEM OPERATION SHORTCUTS
Some keypad operations can be programmed to operate with or without a User
Code.
PROGRAMMING SEQUENCE:
P62E 1E-6E
toggles the options ON and OFF
P62E 1E Memory Display shortcut
P62E 2E Zone Exclude shortcut
P62E 3E Monitor Mode shortcut
P62E 4E Keypad Panic shortcut
P62E 5E Area1 Arming shortcut
P62E 6E Area2 Arming shortcut
OPERATING EXAMPLES:
Arming without shortcut:
[User Code]
Arming with shortcut:
Keypad Panic without shortcut:
[User Code]
Keypad Panic with shortcut:
P62E 1E-6E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
1E, ON: Memory Display shortcut enabled
2E, ON: Zone Exclude shortcut enabled
3E, ON: Monitor Mode shortcut enabled
4E, OFF: Keypad Panic disabled
5E, ON: Area1 Arming shortcut enabled
6E, OFF: Area2 Arming shortcut disabled
NOTES:
• A Tamper Alarm can be caused by the
TAMP input or the J1 link.
• Allocate a User Code to Area2 before
programming Area2 shortcut arming. If
Area 2 is shortcut armed then it will
always remain armed. This will bar entry
into program mode until Area 2 is
disarmed.
SIREN BURST ON AUTO EXCLUDE
This option allows the disabling of the 2 second siren burst at end of Exit Time
which indicates a zone/s has been Auto Excluded.
PROGRAMMING SEQUENCE:
P62E 7E
toggles the option ON and OFF
P62E 7E OFF: Siren burst on Auto Exclude disabled
P62E 7E ON: Siren burst on Auto Exclude enabled
P62E 7E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
ON: Siren burst on Auto Exclude enabled
NOTES:
• RELATED OPTIONS:
P60E 6E
Auto Exclude zones
EXIT TIME X10
This option multiplies the normal exit time by a factor of 10.
PROGRAMMING SEQUENCE:
P62E 8E
toggles the option ON and OFF
P62E 8E OFF: Exit Time is the time set by P28E
P62E 8E ON: Exit Time is multiplied by 10
EXAMPLE:
If P28E = 22 seconds then if P62E 8E is ON, the exit time
is 22 x 10 = 220 seconds.
P62E 8E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: Exit Time x10 disabled
NOTES:
• RELATED OPTIONS:
P28E
Exit Time
1E 2E 3E 4E 5E 6E 7E 8E
ON = Factory default setting.
Shor
tcut
Memor
y Display
Shor
tcut
Zone Exclude
Shor
tcut
Monitor Mode
Shor
tcut
K
eypad P
anic
Shor
tcut
Area1 Ar
ming
Shor
tcut
Area2 Ar
ming
2 sec Siren Auto Exclude
Exit Time x10
OPTION No
DESCRIPTION
P62E
Operation Shortcuts, etc
ON ON ON
ON
ON
Technical Manuals Online! - http://www.tech-man.com