P R O G R A M M I N G
NESS D16 (V4.6) CONTROL PANEL - INSTALLER MANUAL
SWINGER SHUTDOWN
Limits the number of calls made by a zone alarm when Multiple Zone Alarms
are enabled for that zone.
If enabled, multiple reports are limited to three per zone.
PROGRAMMING SEQUENCE:
P89E 4E
toggles the option ON and OFF
P89E 4E OFF: No Swinger Shutdown (unlimited multiple reports)
P89E 4E ON:
Swinger Shutdown enabled (maximum 3 reports per zone)
P89E 4E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
ON: Swinger Shutdown enabled
NOTES:
• This prevents unnecessary multiple
alarms reported to the Central station in
cases, for example, where a door is
‘swinging’ in the wind.
LINE FAULT MONITOR
When this option is enabled, the telephone line is regularly tested. If the
telephone line is not found, the Line light will commence flashing.
PROGRAMMING SEQUENCE:
P89E 5E
toggles the option ON and OFF
P89E 5E OFF: No Line Fault Monitor
P89E 5E ON:
Line Fault Monitor enabled
P89E 5E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: No Line Fault Monitor
NOTES:
• RELATED OPTIONS:
P89E 6E
Line Fault to AUX2
LINE FAULT TO AUX2
When this option is enabled, a telephone line fault condition will turn ON the
AUX2 output. AUX2 will turn OFF when the telephone line is restored.
PROGRAMMING SEQUENCE:
P89E 6E
toggles the option ON and OFF
P89E 6E OFF: No Line Fault output
P89E 6E ON:
Line Fault to AUX2 enabled
P89E 6E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: No Line Fault output
NOTES:
• RELATED OPTIONS:
P89E 5E
Line Fault Monitor
CLOCK TIMING
When set ON, the Test Report Timer uses the panel’s onboard crystal oscillator
instead of the external mains power supply frequency.
Use this option if the mains frequency is not stable over long periods. (Not
necessary in Australia and New Zealand).
PROGRAMMING SEQUENCE:
P89E 7E
toggles the option ON and OFF
P89E 7E OFF: Clock uses mains frequency timing
P89E 7E ON:
Clock uses internal timing
P89E 7E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: Clock uses mains frequency timing
NOTES: