26
26
26
26
26
P R O G R A M M I N G
NESS D16 (V4.6) CONTROL PANEL - INSTALLER MANUAL
TAMPER ALARM / OUTPUT MAPPING
This option selects which outputs will trigger when a Tamper Alarm occurs.
PROGRAMMING SEQUENCE:
P61E 1E-4E
toggles the options ON and OFF
P61E 1E: Tamper Alarm to Reset output
P61E 2E: Tamper Alarm to Strobe output
P61E 3E: Tamper Alarm to Keypad Sonalert output
P61E 4E: Tamper Alarm to Siren output
P61E 1E-4E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
1E-4E, ON: Tamper alarm triggers all
outputs
NOTES:
• A Tamper Alarm can be caused by the
TAMP input or by removing the the J1
link.
KEYPAD PANIC ALARM / OUTPUT MAPPING
This option selects which outputs will trigger when a Keypad Panic alarm
occurs.
PROGRAMMING SEQUENCE:
P61E 5E-8E
toggles the options ON and OFF
P61E 5E:
Keypad
Panic Alarm to Reset output
P61E 6E:
Keypad
Panic Alarm to Strobe output
P61E 7E:
Keypad
Panic Alarm to Keypad Sonalert output
P61E 8E:
Keypad
Panic Alarm to Siren output
P61E 5E-8E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
5E-8E, ON: Panic alarm triggers all outputs
NOTES:
• A Keypad Panic Alarm can be caused by
the PANIC keys on the keypad (* E or **
together, depending on Option P64E6E).
1E 2E 3E 4E 5E 6E 7E 8E
ON = Factory default setting.
Tamper to R
eset output
Tamper to Strobe output
Tamper to Sonaler
t
Tamper to Siren outputKP P
anic to R
eset output
KP P
anic to Strobe output
KP P
anic to Sonaler
t
KP P
anic to Siren output
OPTION No
DESCRIPTION
P61E
Tamper & Panic alarms mapping
ON ON ON ON ON ON ON ON