P R O G R A M M I N G
NESS D16 (V4.6) CONTROL PANEL - INSTALLER MANUAL
ON = Factory default setting.
OPTION No
DESCRIPTION
P75E
Report Misc. Alarms
ON
ON ON ON
ON ON
ON ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
P77E
Report Misc. Restorals
1E
Duress
2E
Medical
3E
K/P & K/S
P
anic
4E
Fire
5E
P
anel T
amper
6E
External T
amper
7E
K
eypad T
amper
8E
Exit Install mode
9E
Radio T
amper
10E
Radio P
anic
11E
Radio Battery
12E
Supervision F
ail
13E
P
anel Battery
14E
Mains F
ail
15E
16E
REPORT MISCELLANEOUS ALARMS
This option selects which Miscellaneous alarms will trigger the dialler to send
Alarm reports to the Central Station.
PROGRAMMING SEQUENCE:
P75E 1E-16E
toggles the option ON and OFF
P75E 1E-16E OFF: Alarm reporting disabled for that miscellaneous alarm
P75E 1E-16E ON: Alarm reporting enabled for that miscellaneous alarm
P75E 1E-16E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
see table
NOTES:
•
0E
will turn all selections OFF
MEMORY E
will turn all selections ON
REPORT MISCELLANEOUS RESTORALS
This option selects which Miscellaneous Alarms will send Restoral reports to
the Central Station. The selections will report Miscellaneous Alarms restored
from the alarmed to the non-alarmed state.
Miscellaneous Alarms which have been selected to send a Restoral report will
always send the Restoral report when a valid code is entered to reset an alarm
or at Opening.
PROGRAMMING SEQUENCE:
P77E 1E-16E
toggles the option ON and OFF
P77E 1E-16E OFF: Restoral reporting disabled for that miscellaneous alarm
P77E 1E-16E ON: Restoral reporting enabled for that miscellaneous alarm
P77E 1E-16E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
see table
NOTES:
• Mains Fail and Battery Fail Restorals are
sent when proper power has been
restored
•
0E
will turn all selections OFF
MEMORY E
will turn all selections ON
1E 2E 3E 4E 5E 6E 7E 8E
ON = Factory default setting.
R
estoral immediately
R
estoral af
ter siren time
R
estoral on Disar
m & seal
R
estoral on Disar
m always
.
.
.
.
OPTION No
DESCRIPTION
P82E
Zone Restoral reporting options
ON
RESTORAL REPORTING OPTIONS
This option selects when the dialler sends zone Restoral reports. Only one of
the following options may be selected.
Restoral reporting options also apply to 24hr zones.
PROGRAMMING SEQUENCE:
P82E 1E-4E
toggles the option ON and OFF
P82E 1E: Send Restoral immediately
P82E 2E: Send Restoral after siren time
P82E 3E: Send Restoral on Disarm & seal
P82E 4E: Send Restoral on Disarm always
P82E 1E-4E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
4E, ON: Always send Restoral on Disarm
NOTES:
• RELATED OPTIONS:
P76E
Report zone restorals