NESS D16 (V4.6) CONTROL PANEL - INSTALLER MANUAL

INSTALLATION PROCEDURES

The location of the main panel housing should be in an area that is within the
protected area of the premises. A linen closet or cupboard are good examples
as these are generally located in the centre of the Premises.

Positioning of the movement detectors should be considered as the incorrect
position may cause unwanted alarms.

1.

Unclip the lid by pushing in the directions of the arrows 1 and 2 as shown below.

2.

Remove the Battery from the base.

3.

Mount the rear panel housing to a secure location.

4.

Insert the PCB stand-offs in the Panel and then plug the circuit board onto the stand-offs.

5.

Wire to the circuit board terminal blocks, as per the wiring instructions shown in this
installation manual.

6.

Replace the Battery.

7.

Insert the panel tamper bracket as shown at left.

8.

Program the control panel as required

1

2

INSTALLING PCB STANDOFFS
& TAMPER BRACKET

HOW TO REMOVE THE LID

PACKING LIST

100-687 Ness D16 Control Panel

Q T Y

Q T Y

Q T Y

Q T Y

Q T Y DESCRIPTION

DESCRIPTION

DESCRIPTION

DESCRIPTION

DESCRIPTION

1

D16 main board

1

D16 housing

1

Ness LCD keypad (100-667)

1

17VAC plug pack

1

12V 7Ah battery (optional)

1

Dialler telephone lead

1

User manual

1

Installer manual

9

2.2K End Of Line resistors

8

4.7K End Of Line resistors

1

Lead assembly for Battery

1

Lead assembly for Internal Tamper

1

Tamper bracket

1

Zone list label

2

Housing cover screws

2

Circuit board standoff

D16 SPECIFICATIONS

Box construction ............ 3mm Polycarbonate (equiv. 1.2mm mild steel)

Box Dimensions ............. 223W x 300H x 85D mm

Plug Pack ...................... 240Vac, output [email protected]

Power Supply ................ 13.8Vdc @ 800mA

Quiescent Current ......... 80mA with 1 Keypad

Operating Voltage ........ 9.5V- 14V dc

Rechargeable Battery ... 12 volt 7.0 Amp/hour, lead acid

Battery Charging current

350mA maximum, current limited

Dynamic Battery Test .... Every Hour and on arming 10.75V with a 5 amp load

Fuses ............................. 2 Amp resettable / sirens & reset.

500mA resettable / 12 volt auxiliary outputs
200 mA resettable / strobe output

INPUTS .......................... 8 physical Zone inputs

(16 Zones inputs with Zone Split enabled)
2 physical 24hr Tamper inputs

End of line resistor ......... 2200 Ohm (or Zone Split 2200 Ohm & 4700 Ohm)
Remote Keypad input .... Proprietary
Maximum Keypads ........ 3
J2 Header ...................... Multi-pin connector for the Ness Radio Interface (100-200)

OUTPUTS
Siren ............................... On board siren driver. Timed output.

Maximum 3 x 8 Ohm horn speakers

Strobe ............................ 12V DC timed output. Maximum 2 x 1 Watt strobe lights
Reset .............................. 12V DC timed output. Maximum 3 x 12V piezo screamers
Equipment power output 13.8V DC output for powering detectors and other equipment.

Maximum 500mA.

J3 Header ...................... Multi-pin connector provides the outputs AUX1, AUX2, ARM1,

ARM2, 12V DC. Also used to connect to the D16 Output Expander
(100-699).

Technical Manuals Online! - http://www.tech-man.com

Содержание D16

Страница 1: ...TION PROGRAMMING MANUAL Ness D16 control panel Installation and programming manual A 15 00 INC GST Revision 4 6 D16 C O N T R O L P A N E L A N D D I A L L E R 16 Technical Manuals Online http www tech man com ...

Страница 2: ...ERTH 08 9328 2511 NEW ZEALAND NFS NZ 64 9 573 0402 Australia s largest designer and manufacturer of high quality security products WWW NESS COM AU D16 V4 6 INSTALLER MANUAL Revision 4 6 March 2003 Document Part Number 890 248 For product 100 687 D16 Control Panel 2003 Ness Security Products Pty Ltd ABN 28 069 984 372 D16installer rev4 6 pmo170303 Specifications may change without notice NESS SECUR...

Страница 3: ...estorals 43 Restoral Reporting options 43 Test Call Interval 44 Time before Next test call 44 Dialling Method 44 Disable Dialler 45 Contact ID format 45 Audible DTMF format 45 Audible Pulse format 45 Contact ID Audible DTMF format 46 Contact ID Audible Pulse format 46 Contact ID Reporting Codes 46 Alternate Dialling 47 Check for dial tone 47 Number of Dialling Attempts 47 Area1 open close reports ...

Страница 4: ...Mode Outputs are separately fused with Automatic Reset Fuses Day Zone feature Temporary Day Zone feature Zone inputs can be split with two end of line resistors so that two detection devices ie reed switches can both be monitored to provide maximum security 30 Event Memory Supports 16 Radio Devices Radio PIRs Radio Reeds etc Supports 14 Radio Keys All inputs and outputs are heavily protected again...

Страница 5: ...tors 8 4 7K End Of Line resistors 1 Lead assembly for Battery 1 Lead assembly for Internal Tamper 1 Tamper bracket 1 Zone list label 2 Housing cover screws 2 Circuit board standoff D16 SPECIFICATIONS Box construction 3mm Polycarbonate equiv 1 2mm mild steel Box Dimensions 223W x 300H x 85D mm Plug Pack 240Vac output 17Vac 1 4A Power Supply 13 8Vdc 800mA Quiescent Current 80mA with 1 Keypad Operati...

Страница 6: ...HITE supplied J2 CONNECTOR Optional NESS RADIO INTERFACE J3 HEADER Provides Open Collector outputs as marked J1 LINK BOX TAMPER PROGRAM LINK Sealed normal state Tamper alarm state Power up with link off to enter installer program mode BATTERY LEADS supplied BATTERY CONNECTION Connect 12V 7Ah backup battery HEARTBEAT LED Constantly flashes 2K2 N O TAMPER SWITCH 761 002 Colour BLACK Supplied with Ne...

Страница 7: ...2V 4K7 4K7 2K2 2K2 2K2 4K7 2K2 2K2 2K2 2K2 2K2 NESS D16 CONTROL PANEL TAMP C EXAMPLE 7 EXAMPLE 3 EXAMPLE 2 EXAMPLE 1 EXAMPLE 6 EXAMPLE 5 EXAMPLE 4 SIREN WIRING N C REED SWITCH DETECTORS 6 WIRE CONNECTION DETECTORS 4 WIRE CONNECTION N C REED SWITCH DETECTORS 6 WIRE CONNECTION DETECTORS 4 WIRE CONNECTION EXTERNAL INTERNAL TAMP C STR RESET SIREN ALTERNATIVE 12V SIRENS 100 172 Ness 12V Internal Siren ...

Страница 8: ...2Volt battery Charge current is limited to 350mA The charge voltage is factory preset at 13 8 V and does not need changing Note A 12 Volt sealed lead acid rechargeable battery must be connected for correct panel operation Observe correct Polarity when connecting the battery Ness Part Number BAT210 12V 7Ah battery EARTH For maximum protection against damage caused by lightning strikes connect a goo...

Страница 9: ...12V 12V DC ouput for accessories Maximum current draw 100mA 0V 12V ground OUTPUTS OUTPUT FUSING The 12V ouputs Siren Reset and Strobe outputs are protected by Automatic Reset electronic fuses These outputs will automatically reset once the overload is removed J3 OPEN COLLECTOR OUTPUTS AUX OUTPUTS The D8 and D16 Aux1 and Aux2 outputs can now be driven by a number of different conditions and alarms ...

Страница 10: ...ERY ZONE Radio Device battery low Device number is indicated by zone lights RADIO BATTERY ARM Radio Key battery low Radio Key number is NOT indicated RADIO TAMPER ZONE Radio Device tamper alarm Device number is indicated by zone lights RADIO MONITOR ZONE Radio Supervision fail Device number is indicated by zone lights KEYPAD INSTALLATION Unclipthetophalfofthekeypadhousingby pushing the top clips d...

Страница 11: ...To Disarm and report a Duress Alarm add any of the digits 5 6 8 or 9 before the User Code when Disarming P75E1E must be enabled Keypad Duress is factory set for silent reporting EXCLUDE ENTER can only be used when the panel is disarmed EXCLUDE CODE ENTER can be used when the panel is armed or disarmed x 2 x 1 x 1 x 2 Hold Press repeatedly to display the last 30 events Both keys together Keypad Pan...

Страница 12: ...ight turns OFF KEY STROKES DESCRIPTION COMMENT 1 2 3 4 5 6 7 8 9 STEP 1 1 8 6 4 7 0 Up to 15 digits 2 3 1 0 0 0 0 0 0 The code is displayed by the keypad lights followed by 3 beeps new The code is displayed by the keypad lights followed by 3 beeps existing See page 46 for further information on the operation of Audible Monitoring 7 2 QUICK START 3 step by step Enter User Program Mode Enter Install...

Страница 13: ... drop out of User Program Mode to Operating Mode if no keypad buttons are pressed for 4 minutes PROGRAM PROGRAM light is ON HOW TO ENTER PROGRAM MODE FROM POWER UP 1 Power up with the PROG link OFF The PROG link or Box Tamper lead must be ON in Operating Mode USING KEYPAD The panel must be Disarmed 1 Press MASTER CODE The keypad will respond with 3 beeps This is User Program Mode PROGRAM light is ...

Страница 14: ...ff the Arm Only feature P11E P25E PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT User Code 1 123 Installer Code 000000 All other codes blank NOTES User Codes can be 3 to 6 digits in length Codes beginning with 0 zero can be programmed but they will not operate the panel this is an alternative method for disabling user codes The MEMORY E function is recommended for deleting user cod...

Страница 15: ...le from 10 990 seconds EXIT DELAY TIME The Exit Delay Time is the time given to secure and depart the premises after the Panel is Armed All zones except 24hr zones are inactive during the Exit Delay time The Exit Delay Time setting is from 1 to 99 seconds PROGRAMMING SEQUENCE P28E existing time is displayed ENTER NEW TIME E new time is displayed EXAMPLE To program Exit Delay to be 85 seconds P28E ...

Страница 16: ... and insensitive to low frequencies Therefore it is not necessary to apply much force to the protected structure rather a very rapid succession of blows The sensitivity has been correctly ad justed when a single blow applied with a soft object e g by hand does not cause an alarm whereas a rapid series of blows using a metal object such as a screw driver blade will cause an alarm 3 2 M H L L RED YE...

Страница 17: ...ally deselected from any other zone type in the DELAY GROUP ENTRY DELAY1 ZONES Entry Delay1 zones operate only in the Armed state When Armed at the expiry of exit time these zones will activate the Entry Delay Timer1 P26E when they are triggered If the panel is not disarmed before the expiry of the Entry Delay Timer1 the alarm outputs will be activated P41E Zone No E turns the options ON P41E Zone...

Страница 18: ...the DELAY GROUP RESET LOCKOUT ZONES All 16 zones and tamper input can be programmed to Lockout i e cause the RESET OUTPUT to sound only once whilst the panel is armed The RESET OUTPUT is then locked out for that alarmed zone until entering a valid code has reset the panel PROGRAMMING SEQUENCE P44E Zone No E toggles the options ON and OFF P44E Zone No E OFF The zone is not a Lockout zone P44E Zone ...

Страница 19: ...eration using simple key strokes TO ENABLE TEMPORARY DAY ZONES To enable Temporary Day Zone selection and operation the Brief Day Alarm feature installer option P64E 2E must be ON If P64E 2E is OFF the Temporary Day Zone feature will be unavailable but Permanent Day Zones will still operate and will sound the programmed output while the zone is unsealed P64E 2E is OFF by default USER COMMANDS In n...

Страница 20: ...e the Zone No E sequence to turn ON zone 1 and zones 9 16 P45E P46E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT No zones assigned to Area 2 NOTES For options P45E and P46E Zone No E toggles the selection ON and OFF Zones assigned to BOTH areas become Common zones If no Area operation is required assign all zones to Area 1 This is also the factory default For example Office A and Offi...

Страница 21: ...signed to NO Areas the code is effectively disabled and will not operate the panel To make a User Code arm or disarm just one Area assign that code only to the required Area Assigning User Codes to Areas has no effect unless zones are also assigned to Areas For this option Zone No E toggles the selection ON and OFF EXAMPLE User codes 1 8 are assigned to AREA 1 EXAMPLE User codes 9 15 are assigned ...

Страница 22: ...les the options ON and OFF P55E Zone No E OFF The zone will not trigger the Strobe output P55E Zone No E ON The zone will trigger the Strobe output P56E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT all ON All zones trigger Keypad Sonalert NOTES 0E will turn all selections OFF MEMORY E will turn all selections ON KEYPAD SONALERT ZONES Selects the zones to trigger the Keypad Sonalert be...

Страница 23: ...t AUX1 output is Pin1 on the J3 header on the main board Once turned on by a zone alarm the output will remain on until the panel is reset disarmed PROGRAMMING SEQUENCE P58E Zone No E toggles the options ON and OFF P58E Zone No E OFF The zone will not trigger the AUX1 output P58E Zone No E ON The zone will trigger the AUX1 output P59E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT all O...

Страница 24: ...60E 2E 3E ON Keyswitch cycles between Arm Monitor and Disarm P60E 2E 3E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT No keyswitch enabled NOTES The keyswitch always Arms Area1 only The keyswitch always Disarms Area1 and Area2 Momentary short circuit across resistor to toggle panel modes Open circuit resistor to trigger keyswitch panic Multiple keyswitches can be used Wire in parallel ...

Страница 25: ...les the option ON and OFF P60E 6E OFF Auto Exclude disabled instant alarm if unsealed at end of Exit Time P60E 6E ON Auto Exclude enabled zone is excluded if unsealed at end of Exit Time P60E 6E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Auto Exclude enabled NOTES RELATED OPTIONS P62E 7E Siren burst on Auto Exclude DISABLE THE DISPLAY The LED indicators on the keypad can be progr...

Страница 26: ...AMMING SEQUENCE P61E 5E 8E toggles the options ON and OFF P61E 5E Keypad Panic Alarm to Reset output P61E 6E Keypad Panic Alarm to Strobe output P61E 7E Keypad Panic Alarm to Keypad Sonalert output P61E 8E Keypad Panic Alarm to Siren output P61E 5E 8E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 5E 8E ON Panic alarm triggers all outputs NOTES A Keypad Panic Alarm can be caused by the ...

Страница 27: ... ON AUTO EXCLUDE This option allows the disabling of the 2 second siren burst at end of Exit Time which indicates a zone s has been Auto Excluded PROGRAMMING SEQUENCE P62E 7E toggles the option ON and OFF P62E 7E OFF Siren burst on Auto Exclude disabled P62E 7E ON Siren burst on Auto Exclude enabled P62E 7E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Siren burst on Auto Exclude en...

Страница 28: ... e to S ir e n o u tp u t OPTION No DESCRIPTION P63E Monitor Day mode output mapping ON ON DAY MODE OUTPUT MAPPING This option selects which outputs are triggered by alarms in Day Mode PROGRAMMING SEQUENCE P63E 5E 8E toggles the options ON and OFF P63E 5E Day Mode to Reset output P63E 6E Day Mode to Strobe output If Brief Day Alarm is enabled P64E 2E then this option sends day alarms to the AUX2 o...

Страница 29: ...ENTRY DELAY 2 Monitor zones can either have the delay types set by options P40E P43E or they can all be assigned to have Entry Delay 2 This allows all Monitor zones to be programmed with the same entry delay time PROGRAMMING SEQUENCE P64E 3E toggles the option ON and OFF P64E 3E OFF Monitor zones behave as programmed by P40E P43E P64E 3E ON Monitor zones all have Entry Delay2 P64E 3E PROGRAM MODE ...

Страница 30: ...ic enabled P64E 6E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Double key Keypad Panic enabled NOTES RELATED OPTIONS P62E 4E Shortcut Keypad Panic The Ness LCD keypad has two buttons labelled KEYPAD FIRE ALARM This option enables the Keypad Fire Alarm Pressing and then activates the dialler and reports a Fire Alarm and triggers the siren The Fire Alarm siren sound is different to ...

Страница 31: ...new time is displayed EXAMPLE To program SUPERVISION TIME to be 4 hours P67E 04E P67E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 24hrs NOTES A setting of less than 3 hours is not recommended The Supervision timer is reset on exit from Installer Program Mode on Arm or Disarm and on reception of the Supervision signal from the particular Radio PIR The Supervision signal from each Supe...

Страница 32: ...SUPERVISION ALERTS KEYPAD SONALERT DELAY ALL SUPERVISION OUTPUTS Setting this option turns the Keypad Sonalert ON when a SUPERVISED RADIO alert occurs The Keypad Sonalert remains ON until any keypad key is pressed Also turning this option ON makes all Supervision outputs delayed by one minute PROGRAMMING SEQUENCE P66E 3E toggles the option ON and OFF P66E 3E OFF Supervision Keypad Sonalert disable...

Страница 33: ...MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Supervision AUX2 output disabled NOTES AUX2 output is Pin2 on the J3 header on the main board RELATED OPTIONS P65E SUPERVISION TIME SPEEDUP X6 Setting this option speeds up the Supervision Time by 6 For instance if P67E is set to 1 hour 60 minutes then this option will reduce it to 10 minutes i e 60 divided by 6 PROGRAMMING SEQUENCE P66E 7E tog...

Страница 34: ...34 34 34 34 34 P R O G R A M M I N G NESS D16 V4 6 CONTROL PANEL INSTALLER MANUAL This page is intentionally blank Technical Manuals Online http www tech man com ...

Страница 35: ... stay accurate long term Avoid using carbon film or 5 tolerance resistors especially when zone splitting Problems may not become evident until some time after the installation due to resistor aging moisture or dust build up If a particular zone will not seal then check the resistance of BOTH the low zone and high zone cabling i e if zone 1 will not seal then also check zone 9 wiring The resistance...

Страница 36: ... FACTORY DEFAULT OFF Radio Key Panic to AUX1 disabled NOTES This option is useful for triggering external devices using Radio Key s Panic button E g lighting garage doors When this option is selected ON the Radio Key Panic function is disabled See TABLE RADIO KEY TO AUX1 RADIO KEY PANIC PULSES AUX1 Setting this option ON changes the action of the Radio Key Panic button so that the AUX1 output is p...

Страница 37: ...RM DISARM This quietens the siren chirps that are made whenever keyswitch or radio key Arming or Disarming is used Arm Disarm Chirps must be enabled at P64E 4E PROGRAMMING SEQUENCE P68E 8E toggles the option ON and OFF P68E 8E OFF Quiet Chirps disabled P68E 8E ON Quiet Chirps enabled P68E 8E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Quiet Chirps disabled NOTES RELATED OPTIONS P...

Страница 38: ...es NOTES This is useful as a Smoke Detector reset output with an optional external relay RELATED OPTIONS P60E 8E Delay ARM1 ARM2 outputs QUIET MONITOR SIREN This option selects the Quiet Siren sound in Monitor Mode The Quiet Siren sound is a continuous beep beep beep sound rather than the normal siren sound PROGRAMMING SEQUENCE P69E 3E toggles the option ON and OFF P69E 3E OFF Normal siren sound i...

Страница 39: ...layed on the keypad 2 Does not give warning beeps 3 Is not saved to MEMORY and the MEMORY display does not flash PROGRAMMING SEQUENCE P69E 6E toggles the option ON and OFF P69E 6E OFF Mains Fail alarm operates normally P69E 6E ON Mains Fail alarm is disabled P69E 6E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Mains Fail alarm normal NOTES This does not affect Dialler mains fail r...

Страница 40: ...Audible Dialling none OPTION No DESCRIPTION FACTORY DEFAULT P72E Account Number 1 0000 P73E Account Number 2 0000 ACCOUNT NUMBER 1 2 Account numbers for identifying the panel to the Central Station Area 1 Open Close reports will report on Account No 1 and Area 2 Open Close reports will report on Account No 2 Zone Alarms can be assigned to report on either Account Number as set by Option P79E All m...

Страница 41: ...en the primary secondary numbers are ignored IF P86E 3E or 4E ARE ENABLED AUDIBLE MONITORING If the Follow Me number is programmed the primary secondary numbers are ignored IF P86E 5E or 6E ARE ENABLED CONTACT ID AUDIBLE The telephone numbers programmed at P70E P71E will be used to send the mesage to the central station The message is also repeated in audible format to the telephone number if any ...

Страница 42: ...OFF MEMORY E will turn all selections ON RELATED OPTIONS P82E 1E Send Restoral immediately P82E 2E Send Restoral after siren time P82E 3E Send Restoral on Disarm seal P82E 4E Send Restoral on Disarm always REPORT MULTIPLE ZONE ALARMS Zones selected for Multiple Zone Alarms will report each time the zone alarms and without a restore being sent The number of reports is a maximum of 15 The number of ...

Страница 43: ...to the non alarmed state Miscellaneous Alarms which have been selected to send a Restoral report will always send the Restoral report when a valid code is entered to reset an alarm or at Opening PROGRAMMING SEQUENCE P77E 1E 16E toggles the option ON and OFF P77E 1E 16E OFF Restoral reporting disabled for that miscellaneous alarm P77E 1E 16E ON Restoral reporting enabled for that miscellaneous alar...

Страница 44: ...reset the time that test calls are sent E g Our example panel is sending test calls at 1am and you want to change it to 2am If you are programming the panel at 6pm enter P84E 4E 4 x 2 8hrs Therefore 6pm 8hrs 2am PROGRAMMING SEQUENCE P84E existing Time Before Next Test Call is displayed See note 3 ENTER NEW TIME E new Time Before Next Test Call is displayed P84E PROGRAM MODE LEVEL Installer Remote ...

Страница 45: ...N P86E 2E ON Contact ID format enabled P86E 2E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Contact ID format enabled NOTES Only one option in the range P86E 1E 6E is allowed to be ON AUDIBLE DTMF FORMAT For Audible Monitoring to any telephone or mobile phone The last digit of the Account number and the zone alarm are sent in Audible DTMF format The message is repeated for 45 secon...

Страница 46: ...s fixed as shown in the Contact ID Codes Table THE MESSAGE TAKES THE FORM OF ssss Client Code 0000 9999 Q 1 New Event or Open Q 3 Restore or Close dd User ID 1 to 15 zz Zone ID 1 to 16 aa 01 Area 1 aa 02 Area 2 aa 01 Monitor area aa 00 24 Hr Area k Checksum 0 to 0f hex CONTACT ID CODES TABLE CONTACT ID CODES TABLE CONTACT ID CODES TABLE CONTACT ID CODES TABLE CONTACT ID CODES TABLE REPORT NAME PRE...

Страница 47: ...ial without dial tone P87E 2E ON Dial only with dial tone P87E 2E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Dial only with dial tone NOTES NUMBER OF DIALLING ATTEMPTS Sets the number of dialling attempts when sending reports OFF sets a maximum 10 dial attempts before a 5 minute sleep and 10 more re tries if unsuccessful ON allows a maximum of 4 dial attempts before a 5 minute sl...

Страница 48: ...NG SEQUENCE P88E 2E toggles the option ON and OFF P88E 2E OFF No AREA2 Open Close reports P88E 2E ON AREA2 Open Close reports enabled P88E 2E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No AREA2 Open Close NOTES SIREN CHIRP ON KISS OFF Selects a 2 Second Siren burst on a successful Closing report This is used to give audible indication that the dialler has successfully sent the A...

Страница 49: ... and OFF P88E 6E OFF Closing Reports sent on Arming P88E 6E ON Closing Reports sent at end of Exit Time P88E 6E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Closing Reports sent on Arming NOTES RELATED OPTIONS P88E 1E AREA1 Open Close reports P88E 2E AREA2 Open Close reports MANUAL EXCLUDE REPORT Enables Manual Exclude Reports for Zones 1 16 Exclude Reports for 24hr zones are sent...

Страница 50: ...ins Fail report is sent immediately the power fails PROGRAMMING SEQUENCE P89E 2E toggles the option ON and OFF P89E 2E OFF Mains Fail reports immediately P89E 2E ON Mains Fail report is delayed by 1 hour P89E 2E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Mains Fail report is delayed NOTES LISTEN IN TO DIALLER This is a diagnostic feature for installers Listen In is turned on for ...

Страница 51: ...onitor enabled P89E 5E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Line Fault Monitor NOTES RELATED OPTIONS P89E 6E Line Fault to AUX2 LINE FAULT TO AUX2 When this option is enabled a telephone line fault condition will turn ON the AUX2 output AUX2 will turn OFF when the telephone line is restored PROGRAMMING SEQUENCE P89E 6E toggles the option ON and OFF P89E 6E OFF No Line F...

Страница 52: ... D16 telephone output and an on site computer with modem Direct Connect simulates a telephone line ring and makes the D16 connect immediately to the telephone line SEQUENCE The panel must be in Installer Program mode Dial the panel using NessComms While NessComms is ringing the panel press P90E 2E This forces the panel to pick up the line and comms can start P90E 2E PROGRAM MODE LEVEL Installer Re...

Страница 53: ...Remote by PC FACTORY DEFAULT OFF No Remote Event Reporting NOTES REMOTE STATUS REPORTING Enables Remote Status Reporting PROGRAMMING SEQUENCE P90E 6E toggles the option ON and OFF P90E 6E OFF No Remote Status Reporting P90E 6E ON Remote Status Reporting enabled P90E 6E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Remote Status Reporting NOTES REMOTE AUX CONTROL Enables the remo...

Страница 54: ...e PANEL RESET This function resets the microprocessor The effect is the same as powering down and powering up again Panel Reset operates in User and Installer program mode P88888888E eight 8 s Panel Reset PANEL SOFTWARE VERSION This function displays the panel software version when in program mode Displayed in decimal format by the zone LEDs Example version 4 5 is displayed by flashing 4 followed ...

Страница 55: ...lank NOTES This option DOES NOT clear the Installer Code CLEAR RADIO DEVICES This option clears all Radio Device Codes Except Radio Keys assigned to Radio Codes Options P101E P116E are defaulted D16 Radio Devices PROGRAMMING SEQUENCE P95E Clears Radio Device Codes P95E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT not applicable These options allow selective restoring of various factor...

Страница 56: ... P16E 6E User Code 7 P17E 7E User Code 8 P18E 8E User Code 9 P19E 1E User Code 10 P20E 2E User Code 11 P21E 3E User Code 12 P22E 4E User Code 13 P23E 5E User Code 14 P24E 6E User Code 15 P25E 7E Installer Code P99E Installer Code 000000 P09E P10E ENABLE AS A RADIO CODE CODE TABLE PROGRAMMING RADIO KEYS Radio Keys can be assigned to take the place of User Codes 2 to 15 User Code 1 is always a Keypa...

Страница 57: ... Radio Device Restore the reed switch place the magnet next to the switch A If the Radio Device is accepted the READY light will turn off the ARMED light will turn on and 3 beeps will sound B The MEMORY light will turn on to indicate that this device sends Restorals C If the READY light stays on and a warning beep sounds the Radio Device is already assigned to another zone and must be cleared from...

Страница 58: ...he radio signal from any Ness radio device The strength of the radio signal received is displayed on the zone lights 1 8 and beeped by the keypad The higher the number displayed and beeped the stronger the signal received TEST SEQUENCE Enter the option for the radio device to be tested For Radio Keys options P12E P25E For all other radio devices options P101E P116E Press 3E Trigger the radio devic...

Страница 59: ...E option ON and a radio code has been programmed for that zone then the supervision is active This means that the radio detector does not need to have its SUPER enabled via header link for the SUPERVISED timeout to occur Useful as an inactivity alarm A zone supervision failure always flashes the identifying ZONE light and the RADIO light RK1 RADIO KEY PENDANT 100 665 RK3 RADIO KEY 3 BUTTON RK4 RAD...

Страница 60: ...e needed using only one Expander PROGRAMMING SEQUENCE P117E 2E toggles the option ON and OFF P117E 2E OFF No Alternate Format P117E 2E ON Alternate Format enabled P117E 2E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Alternate Format NOTES The 2nd Expander plugs into the 6 way header on the 1st Expander This 6 way header on the Expander cannot be used for any other purpose IF A...

Страница 61: ...ne is also selected in P119 to zone latch then an output will only occur whenever a zone is in alarm and is also unsealed In this case when the zone reseals the output automatically goes off again A further zone unseal will turn the zone Expander output On again PROGRAMMING SEQUENCE P118E 1E 16E toggles the option ON and OFF P118E 1E 16E OFF Output Expander disabled for that zone P118E 1E 16E ON O...

Страница 62: ...mper Panic Keypad Panic Radio Panic Medical alarm Fire alarm Exit from installer program mode External Tamper Internal Panel Tamper Keypad Tamper Radio Tamper Mains Fail Panel Battery Fail RADIO Battery Fail RADIO Supervision Fail The D16 will allow a user to call in to the panel using a standard DTMF telephone and remotely Arm or Disarm all areas and also turn on or off Aux 1 and Aux 2 To maintai...

Страница 63: ... Line Fault to AUX2 Internal clock timing OFF OFF Sonalert Zones All zones 3E Radio Panic Toggles AUX1 OFF 1E Enable Up Download OFF Siren Zones All zones 4E Radio Panic Pulses AUX1 OFF 2E Enable Direct Connect OFF Aux 1 Zones none 5E Radio Arm unseal warning OFF 3E Enable Remote Arming OFF Aux 2 Zones none 6E 24hr Zone Fire Siren OFF 4E Enable Remote Disarming OFF 1E Entry Beeps ON 7E RK4 AUX but...

Страница 64: ...1 12 13 14 15 16 2002 Ness Security Products P26E ENTRY DELAY TIME 1 Seconds Seconds Seconds Minutes P27E ENTRY DELAY TIME 2 P28E EXIT DELAY TIME P29E SIREN RESET TIME CODE OPTION No CODE HOLDER AREA 1 AREA 2 RADIO KEY CODE Y N User Code 1 P11E Master Code Keypad Code only User Code 2 P12E User Code 3 P13E User Code 4 P14E User Code 5 P15E User Code 6 P16E User Code 7 P17E User Code 8 P18E User Co...

Отзывы: