NESS D16 (V4.6) CONTROL PANEL - INSTALLER MANUAL
D16 OPERATION SUMMARY
ARM
TEMPORARY DAY
ZONES
DISARM
MONITOR MODE
PANIC
KEYPAD DURESS
EXCLUDING ZONES
VIEW MEMORY
(Monitor Shortcut
must be ON, P62E 3E)
Press and hold for 4 seconds
(P68E 3E & 4E must be OFF)
Press OFF button twice within 4 seconds
or ON button twice within 4 seconds
P69E 5E must be ON
or
The panel must be in
a Disarmed state first.
To Disarm and/or reset
alarms.
The panel must be in
a Disarmed state first.*
The panel must be in
a Disarmed state first.*
P64E 2E must be on for
enable the use of
Temporary Day Zones.
* NOTE ON ARMING: Normal user codes can arm the panel only if it is fully disarmed first. User codes that are programmed to be Arm Only
codes can arm the panel from Monitor mode or from the disarmed state.
OPERATION
LCD KEYPAD
RADIO KEY
To Disarm and report a Duress Alarm, add any of the digits 5, 6, 8 or 9 before the User Code
when Disarming.
P75E1E must be enabled
Keypad Duress is factory
set for silent reporting
E ENTER can only
be used when the panel is
disarmed.
E CODE + ENTER
can be used when the panel
is armed or disarmed.
x 2
x 1
x 1
x 2
Hold
Press
repeatedly to display the last 30 events
Both keys together
(Keypad Panic Shortcut
must be ON, P62E 4E)
or...
or...
or...
[Zone No.]
[Zone No.]
[Zone No.]
[
]
5, 6, 8 or 9
[User Code]
[User Code]
[User Code]
[User Code]
(Arming Shortcut
must be ON, P62E 5E)
or...
[User Code]
Enter the zone numbers to be Excluded
To exit Exclude mode
To exit Memory mode
Enters Temporary Day Zone selection mode.
Enables/disables Temporary Day mode.
Select zone/s to be Temporary Day Zones.
Saves changes and exits Temporary Day Zone selection mode.
(Exclude Shortcut
must be ON, P62E 2E)
or...
[User Code]
(Memory Shortcut
must be ON, P62E 1E)
or...
[User Code]
View Memory can only be
used when the panel is
disarmed.