Troubleshooting 8-51
About System Log when re-starting the system on Windows Server 2003
Type:
Warning
Source:
E100B
Event ID:
4
Description: Adapter Intel(R) PRO/100 Network Connection: Adapter Link Down
→
When re-starting the system without connecting the network cable, this log may
be found in system event log.
But this has no effect on the behavior of LAN driver.
Confirm that the system is connected with the LAN cable properly.
If 100Base LAN port is not utilized, disable 100Base LAN on device manager or
disable it on BIOS configuration. Then, the log will not be registered.
Event logs in using SNMP Service in Windows Server 2003
Event Type:
Warning
Event Source:
EvntAgnt
Event Category: None
Event ID:
1015
Description:
TraceLevel parameter not located in registry;
Default trace level used is 32.
Event Type:
Warning
Event Source:
EvntAgnt
Event Category: None
Event ID:
1003
Description:
TraceFileName parameter not located in registry;
Default trace file used is .
→
The system will not be affect by these event logs. SNMP will not be affected
either, so that you can ignore these logs.
A PCI board is not recognized.
T
Is the PCI board installed correctly?
→
Confirm that the PCI board is installed in the slot correctly.
T
Is the proper IRQ assigned for the board?
→
Assign the proper IRQ by referring to the Chapter 4.
T
Is "Disabled" specified in [Option ROM] for the slot to install SCSI card (excluding
the array board used for OS boot)?
→
Check the settings with the BIOS setup utility.
<Menus to check: [Advanced] - [PCI Configuration] - [PCI Slot n] (n: PCI slot
number of installed board) - [Option ROM Scan]>
T
Is "Disabled" specified in [Option ROM] for the slot for added network board which
is not used for network boot?
→
Check the settings with the BIOS setup utility.
<Menus to check: [Advanced] - [PCI Configuration] - [PCI Slot n] (n: PCI slot
number of installed board) - [Option ROM Scan]>
Содержание N8100-1220F
Страница 7: ......
Страница 8: ......
Страница 9: ......
Страница 38: ...1 18 Notes on Using Your Server This page is intentionally left blank...
Страница 76: ...2 38 General Description This page is intentionally left blank...
Страница 187: ...Configuring Your Server 4 83 3 Setting menu for VD 0 is displayed...
Страница 494: ...F 4 Product Configuration Record Table This page is intentionally left blank...