CHAPTER 19 IEBus CONTROLLER (V850/SB2)
User’s Manual U13850EJ4V0UM
456
19.3.2 Internal registers
The internal registers incorporated in the IEBus controller are described below.
(1) IEBus control register (BCR)
Figure 19-11. IEBus Control Register (BCR)
After reset: 00H
RW Address: FFFFF3E0H
<7>
<6>
<5>
<4>
<3>
2
1
0
BCR
ENIEBUS MSTRQ
ALLRQ ENSLVTX ENSLVRX
0
0
0
ENIEBUS
Communication enable flag
0
IEBus unit stopped
1
IEBus unit active
MSTRQ
Master request flag
0
IEBus unit not requested as master
1
IEBus unit requested as master
ALLRQ
Broadcast request flag
0
Individual communication requested
1
Broadcasting communication requested
ENSLVTX
Slave transmission enable flag
0
Slave transmission disabled
1
Slave transmission enabled
ENSLVRX
Slave reception enable flag
0
Slave reception disabled
1
Slave reception enabled
Cautions 1. While the IEBus is operating as the master, writing to the BCR register (including bit
manipulation instructions) is disabled until either the end of that communication or frame,
or until communication is stopped by the occurrence of an arbitration-loss communication
error. Master requests cannot therefore be multiplexed. However, if the IEBus is specified
as a slave while a master request is being held pending, the BCR can be written to at the
end of communication to clear the communication end/frame end flag. This is also the case
when communication has been forcibly stopped (ENIEBUS flag = 0).
2. If a bit manipulation instruction for the BCR register conflicts with a hardware reset of the
MSTRQ flag, the BCR register may not operate normally. The following countermeasures
are recommended in this case.
••••
Because the hardware reset is instigated in the acknowledgement period of the slave
address field, be sure to observe Caution 1 of (b) Master request flag (MSTRQ) below.
••••
Be sure to observe the caution above regarding writing to the BCR register.
Содержание MPD703030A
Страница 2: ...User s Manual U13850EJ4V0UM 2 MEMO ...
Страница 514: ...User s Manual U13850EJ4V0UM 514 MEMO ...