CHAPTER 7 TIMER/COUNTER FUNCTION
User’s Manual U13850EJ4V0UM
215
Figure 7-39. TM6, TM7 Timer Clock Selection Registers 60, 61, 70, 71 (TCL60, TCL61, TCL70, and TCL71)
After reset: 00H
R/W
Address: FFFFF284H, FFFFF294H
7
6
5
4
3
2
1
0
TCLn0
0
0
0
0
0
TCLn2
TCLn1
TCLn0
(n = 6, 7)
After reset: 00H
R/W
Address: FFFFF28EH, FFFFF29EH
7
6
5
4
3
2
1
0
TCLn1
0
0
0
0
0
0
0
TCLn3
(n = 6, 7)
Count clock selection
f
XX
TCLn3
TCLn2
TCLn1
TCLn0
Count clock
20 MHz
Note
12.58 MHz
0
0
0
0
Setting prohibited
−
−
0
0
0
1
Setting prohibited
−
−
0
0
1
0
f
XX
/4
200 ns
318 ns
0
0
1
1
f
XX
/8
400 ns
636 ns
0
1
0
0
f
XX
/16
800 ns
1.3
µ
s
0
1
0
1
f
XX
/32
1.6
µ
s
2.5
µ
s
0
1
1
0
f
XX
/64
3.2
µ
s
5.1
µ
s
0
1
1
1
f
XX
/128
6.4
µ
s
10.2
µ
s
1
0
0
0
Setting prohibited
−
−
1
0
0
1
Setting prohibited
−
−
1
0
1
0
f
XX
/256
12.8
µ
s
20.3
µ
s
1
0
1
1
f
XX
/512
25.6
µ
s
40.7
µ
s
1
1
0
0
Setting prohibited
−
−
1
1
0
1
Setting prohibited
−
−
1
1
1
0
Setting prohibited
−
−
1
1
1
1
TM0 overflow signal
−
−
Note
Only for the V850/SB1.
Cautions 1. When TCLn0 and TCLn1 are overwritten by different data, write after temporarily
stopping the timer.
2. Always set bits 3 to 7 of TCLn0 and bits 1 to 7 of TCLn1 to 0.
Remark
When connected in cascade, the settings of TCL73 to TCL70 of TM7 are invalid.