7-8 Troubleshooting
On-screen error message
Recommended action
0B83 BMC IBF or OBF check
failed
1. Take one of the following measures to reboot (reset) the
modular server.
* Issue an OS command.
* Press
Ctrl
+
Alt
+
Del
.
* Issue a command from Web browser of EXPRESSSCOPE
Engine or NEC ESMPRO Manager.
2. Take one of the following measures to power off the modular
server and then on.
* Power off the modular server from OS, then press the
POWER/SLEEP switch to power on.
* Press the POWER/SLEEP switch to power off the modular
server, then press it again to power on.
* Issue a command from Web browser of EXPRESSSCOPE
Engine or NEC ESMPRO Manager.
3. Power off the modular server by issuing an OS command or
press the POWER/SLEEP switch. Take the modular server
out of the Module Enclosure, and install it again. Then, press
the POWER/SLEEP switch to turn on the modular server.
4. If the same error persists, contact your service representative.
0B8A BMC SEL area full
1. Run BIOS SETUP, select [Server] - [Event Log Configuration]
- [Clear All Error Logs] to clear the IPMI system event logs.
2. If the same error persists, contact your service representative.
Note: You can make a backup copy of IPMI system event logs
through the Off-line Maintenance Utility before clearing the
IPMI system event logs on BIOS SETUP.
0B8B BMC progress check
timeout
0B8D Could not redirect the
console - BMC Busy -
0B8E Could not redirect the
console - BMC Error -
0B8F Could not redirect the
console - BMC Parameter
Error -
1. Take one of the following measures to reboot (reset) the
modular server.
* Issue an OS command.
* Press
Ctrl
+
Alt
+
Del
.
* Issue a command from Web browser of EXPRESSSCOPE
Engine or NEC ESMPRO Manager.
2. Take one of the following measures to power off the modular
server and then on.
* Power off the modular server from OS, then press the
POWER/SLEEP switch to power on.
* Press the POWER/SLEEP switch to power off the modular
server, then press it again to power on.
* Issue a command from Web browser of EXPRESSSCOPE
Engine or NEC ESMPRO Manager.
3. Power off the modular server by issuing an OS command or
press the POWER/SLEEP switch. Take the modular server
out of the Module Enclosure, and install it again. Then, press
the POWER/SLEEP switch to turn on the modular server.
4. If the same error persists, contact your service representative.
Содержание EXPRESS5800/100 SERIES N8100-1635F
Страница 12: ...vi Appendix A Specifications A 1 Appendix B Using a Client Computer Which Has a CD Drive B 1 ...
Страница 82: ...5 4 Installing and Using Utilities This page is intentionally left blank ...
Страница 126: ...7 36 Troubleshooting When you use a remote console 6 Select a desired tool to start it ...
Страница 147: ...Upgrading Your Modular Server 8 13 7 Secure the hard disk drive bracket to the modular server with four screws ...
Страница 148: ...8 14 Upgrading Your Modular Server This page is intentionally left blank ...
Страница 150: ...A 2 Specifications This page is intentionally left blank ...
Страница 152: ...B 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...