7-14 Troubleshooting
Other Messages
Messages displayed on upper line
When STATUS lamp is lighting in green:
On-screen
message
Description
Action
Prepare To Boot
POST completes
normally.
This is not an error.
When STATUS lamp is off:
On-screen
message
Description
Action
PCI Bus SERR 01
A system error was
detected on chipset.
PCI Bus SERR 07
A system error was
detected on LAN1 device.
PCI Bus SERR 09
A system error was
detected on LAN2 device.
PCI Bus PERR 01
A system error was
detected on chipset.
PCI Bus PERR 07
A system error was
detected on LAN1 device.
PCI Bus PERR 09
A system error was
detected on LAN2 device.
1. Take one of the following measures to
reboot (reset) the modular server.
* Issue an OS command.
* Press
Ctrl
+
Alt
+
Del
.
* Issue a command from Web browser of
EXPRESSSCOPE Engine or NEC
ESMPRO Manager.
2. Take one of the following measures to power
off the modular server and then on.
* Power off the modular server from OS,
then press the POWER/SLEEP switch to
power on.
* Press the POWER/SLEEP switch to power
off the modular server, then press it again
to power on.
* Issue a command from Web browser of
EXPRESSSCOPE Engine or NEC
ESMPRO Manager.
3. If the same error persists, contact your
service representative.
Содержание EXPRESS5800/100 SERIES N8100-1635F
Страница 12: ...vi Appendix A Specifications A 1 Appendix B Using a Client Computer Which Has a CD Drive B 1 ...
Страница 82: ...5 4 Installing and Using Utilities This page is intentionally left blank ...
Страница 126: ...7 36 Troubleshooting When you use a remote console 6 Select a desired tool to start it ...
Страница 147: ...Upgrading Your Modular Server 8 13 7 Secure the hard disk drive bracket to the modular server with four screws ...
Страница 148: ...8 14 Upgrading Your Modular Server This page is intentionally left blank ...
Страница 150: ...A 2 Specifications This page is intentionally left blank ...
Страница 152: ...B 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...