Configuring Your Modular Server 4-21
BMC LAN Configuration Submenu
Option
Parameter
Description
Your Setting
Shared BMC
LAN
[Disabled]
Enabled
Set to [Disabled] to use the
management LAN port for
management LAN.
When set to [Enabled], the LAN port 1
can be used for management LAN
while sharing with the standard LAN.
When set to [Enabled], the
management LAN port is disabled.
LAN
Connection
Type
[Auto Negotiation]
100Mbps Full Duplex
100Mbps Half Duplex
10Mbps Full Duplex
10Mbps Half Duplex
Specify the connection type for
management LAN port.
IP Address
Variable
Specify an IP address for
management LAN.
Subnet Mask
Variable
Specify a subnet mask for
management LAN.
Default
Gateway
Variable
Specify a default gateway for
management LAN.
DHCP
[Disabled]
Enabled
Set to [Enabled] to obtain an IP
address from DHCP server
automatically. If you intend to specify
an IP address manually, set to
[Disabled].
Web Interface
HTTP
Disabled
[Enabled]
Set to [Enabled] to use HTTP
communication for Web interface.
HTTP Port
Number
Variable
Specify the TCP port number which
the management LAN uses for HTTP
communication.
HTTPS
Disabled
[Enabled]
Set to [Enabled] to use HTTPS
communication for Web interface.
HTTPS Port
Number
Variable
Specify the TCP port number which
the management LAN uses for HTTPS
communication.
Command Line Interface
Telnet
Disabled
[Enabled]
Set to [Enabled] to use Telnet
communication as a command line
interface.
Telnet Port
Number
Variable
Specify the TCP port number to be
used for Telnet communication.
SSH
Disabled
[Enabled]
Set to [Enabled] to use SSH
communication as a command line
interface.
SSH Port
Number
Variable
Specify the TCP port number to be
used for SSH communication.
Clear BMC
Configuration
[Enter] *
Press
Enter
and select "Yes" to
initialize the BMC configuration.
[ ]: Factory-set
Содержание EXPRESS5800/100 SERIES N8100-1635F
Страница 12: ...vi Appendix A Specifications A 1 Appendix B Using a Client Computer Which Has a CD Drive B 1 ...
Страница 82: ...5 4 Installing and Using Utilities This page is intentionally left blank ...
Страница 126: ...7 36 Troubleshooting When you use a remote console 6 Select a desired tool to start it ...
Страница 147: ...Upgrading Your Modular Server 8 13 7 Secure the hard disk drive bracket to the modular server with four screws ...
Страница 148: ...8 14 Upgrading Your Modular Server This page is intentionally left blank ...
Страница 150: ...A 2 Specifications This page is intentionally left blank ...
Страница 152: ...B 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...