Troubleshooting 7-11
On-screen error message
Recommended action
0BD1 1st SMBus device Error
detected
1. Take one of the following measures to reboot (reset) the
modular server.
* Issue an OS command.
* Press
Ctrl
+
Alt
+
Del
.
* Issue a command from Web browser of EXPRESSSCOPE
Engine or NEC ESMPRO Manager.
2. Take one of the following measures to power off the modular
server and then on.
* Power off the modular server from OS, then press the
POWER/SLEEP switch to power on.
* Press the POWER/SLEEP switch to power off the modular
server, then press it again to power on.
* Issue a command from Web browser of EXPRESSSCOPE
Engine or NEC ESMPRO Manager.
3. Power off the modular server by issuing an OS command or
press the POWER/SLEEP switch. Take the modular server
out of the Module Enclosure, and install it again. Then, press
the POWER/SLEEP switch to turn on the modular server.
4. If the same error persists, contact your service representative.
0BD4 2nd SMBus device Error
detected
0BD7 3rd SMBus device Error
detected
0BDA 4th SMBus device Error
detected
0BDD 5th SMBus device Error
detected
0BE0 6th SMBus device Error
detected
1. Take one of the following measures to reboot (reset) the
modular server.
* Issue an OS command.
* Press
Ctrl
+
Alt
+
Del
.
* Issue a command from Web browser of EXPRESSSCOPE
Engine or NEC ESMPRO Manager.
2. Take one of the following measures to power off the modular
server and then on.
* Power off the modular server from OS, then press the
POWER/SLEEP switch to power on.
* Press the POWER/SLEEP switch to power off the modular
server, then press it again to power on.
* Issue a command from Web browser of EXPRESSSCOPE
Engine or NEC ESMPRO Manager.
3. Power off the modular server by issuing an OS command or
press the POWER/SLEEP switch. Take the modular server
out of the Module Enclosure, and install it again. Then, press
the POWER/SLEEP switch to turn on the modular server.
4. If the same error persists, contact your service representative.
8100
Memory Error detected in
DIMM #1
8101
Memory Error detected in
DIMM #2
1. Run BIOS SETUP and select [Advanced] - [Memory
Configuration] - [Memory Retest] - [Yes] and reboot the
modular server.
2. DIMM may be faulty. Replace it with new one.
3. If the same error persists, contact your service representative.
8150
NVRAM Cleared By
Jumper
Contact your service representative.
8151
Password Cleared By
Jumper
Содержание EXPRESS5800/100 SERIES N8100-1635F
Страница 12: ...vi Appendix A Specifications A 1 Appendix B Using a Client Computer Which Has a CD Drive B 1 ...
Страница 82: ...5 4 Installing and Using Utilities This page is intentionally left blank ...
Страница 126: ...7 36 Troubleshooting When you use a remote console 6 Select a desired tool to start it ...
Страница 147: ...Upgrading Your Modular Server 8 13 7 Secure the hard disk drive bracket to the modular server with four screws ...
Страница 148: ...8 14 Upgrading Your Modular Server This page is intentionally left blank ...
Страница 150: ...A 2 Specifications This page is intentionally left blank ...
Страница 152: ...B 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...