7-4 Troubleshooting
ERROR MESSAGES
If an error occurs in the modular server, an error message appears.
POST Error Messages
Powering on the modular server automatically starts the self-diagnostic program, POST (Power On
Self-Test). When the POST detects any error, it displays an error message and its measure on the
display unit.
Follow the table below to troubleshoot such errors.
IMPORTANT:
Take a note on the messages and beep patterns
displayed before consulting with your service representative. Alarm
messages are useful information for maintenance.
NOTES:
The POST error messages listed below are for modular server itself.
The POST error message contains POST error code. For example,
"8100" represents the error code in the message [8100: Memory
Error detected in DIMM #1].
On-screen error message
Recommended action
0200
Failure Fixed Disk
Contact your service representative.
0230
System RAM Failed
0231
Shadow RAM Failed
0232
Extend RAM Failed
1. Take one of the following measures to reboot (reset) the
modular server.
* Issue an OS command.
* Press
Ctrl
+
Alt
+
Del
.
* Issue a command from Web browser of EXPRESSSCOPE
Engine or NEC ESMPRO Manager.
2. Take one of the following measures to power off the modular
server and then on.
* Power off the modular server from OS, then press the
POWER/SLEEP switch to power on.
* Press the POWER/SLEEP switch to power off the modular
server, then press it again to power on.
* Issue a command from Web browser of EXPRESSSCOPE
Engine or NEC ESMPRO Manager.
3. Check installation status of DIMMs.
4. Replace the DIMM.
5. If the same error persists, contact your service representative.
Содержание EXPRESS5800/100 SERIES N8100-1635F
Страница 12: ...vi Appendix A Specifications A 1 Appendix B Using a Client Computer Which Has a CD Drive B 1 ...
Страница 82: ...5 4 Installing and Using Utilities This page is intentionally left blank ...
Страница 126: ...7 36 Troubleshooting When you use a remote console 6 Select a desired tool to start it ...
Страница 147: ...Upgrading Your Modular Server 8 13 7 Secure the hard disk drive bracket to the modular server with four screws ...
Страница 148: ...8 14 Upgrading Your Modular Server This page is intentionally left blank ...
Страница 150: ...A 2 Specifications This page is intentionally left blank ...
Страница 152: ...B 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...