54D0700
41
BDV Series Gas Fireplace
FP1916
AC box
8/08
Screw
Guiding Block
Connector Hole
Connector Pin
Control Box
AC Box
Figure 56 - Connect AC Box to Control Box
OptIONAL FAN BLOWER SyStEM
To Junction Box
In Fireplace
WHITE
BLACK
WHITE
BLACK
BLACK
WHITE
GREEN
Connector
Pin To Contro l Box
Optional
AC Box
{
{
Optional
Light
Optional
AUX
Control Box
Blower
(300 W
Max)
FP2103
BDV fan wiring
Figure 57 - Blower Wiring Diagram
FP2103
W
A
RNING
Electrical Grounding Instructions: This appliance is
equipped with a three-prong (grounding) plug for
your protection against shock hazard and should
be plugged directly into a properly grounded three
prong receptacle.
7. Secure the AC box to the control box using
screw provided.
Figure 56
8. Plug in wiring harness to the back of AC box.
9. Connect the blower according to the wiring
diagram.
Figure 57
NOtE:
Be sure to use the
wires marked ‘Blower’.
10. Replace glass frame .
11. Plug the AC box plug to the junction box.
Figure
57
12. To test blower operation. Turn the fireplace
on. Turn blower on. The blower should turn on
within five (5) minutes. Refer to the operating
instructions on Signature Command remote
control for complete operation instructions.
Finishing
Re-install the lower access panel.
W
A
RNING
Electrical connections should only be performed
by a qualified licensed electrician. Main power
supply must be turned off before connecting the
fan to the main electrical power supply or perform-
ing service.
NO
tE
The black and white wires on the AC box wiring
harness are marked ‘Blower’, ‘Light’ and ‘Aux’
It is important to use the wires marked ‘Blower’
or the control will not work correctly.