KIT CONTENTS (See Figure 1):

 1 ea. Robertshaw NG Regulator Kit (A)

 1 ea. #37 NG main burner orifice (30,000 BTU’s) (B)

 1 ea. Nova SIT NG pilot orifice (C)

 1 ea. Instruction Sheet

TOOLS NEEDED (See Figure 2):

5/32” Allen Wrench Or T-Handle Wrench

#2 Phillips Screwdriver 

1/2” Open End Wrench

DESIGNER™ GaS CONvERSION INSTRuCTIONS LP TO NG

CaT. NO. H5428, MODEL DBv-CK-LP TO NG

INSTaLLaTION INSTRuCTIONS FOR CONvERTING FROM PROPaNE GaS (LP) TO 
NaTuRaL GaS (NG).  FOR uSE wITH THE DESIGNER™ DIRECT vENT GaS FIREPLaCE INSERTS

775,239M 

Rev. a, 08/2008

HEARTH PRODUCTS

KITS AND ACCESSORIES

       

waRNING

This conversion kit shall be installed by a qualified 

service agency in accordance with the manufacturer's 

instructions and all applicable codes and requirements 

of the authority having jurisdiction.  If the information 

in these instructions is not followed exactly, a fire, 

explosion or production of carbon monoxide may result 

causing property damage, personal injury or loss of 

life.  The qualified service agency performing this 

installation is responsible for the proper installation of 

this kit and assumes responsibility for this conversion. 

The installation is not proper and complete until the 

operation of the converted appliance is checked as 

specified in the manufacturers instructions supplied 

with the kit. 

 IMPORTaNT LE CaNaDa SEuLEMENT

La conversion devra être effectuée conformément 

aux recommandations des autorités provinciales 

ayant juridiction et conformément aux exigences 

du code d'installation CaN/CSa B149.1 .

         IMPORTaNT CaNaDa

The conversion shall be carried out in accordance with 

the requirements of the provincial authorities having 

jurisdiction and in accordance with the requirements 

of the CaN/CSa B149.1 Installation code.

            

avERTISSEMENT

Cet équipement de conversion sera installé par une 

agence qualifiée de service conformément aux instruc-

tions du fabricant et toutes exigences et codes applica-

bles de l'autorisés avoir la juridiction.  Si l'information 

dans cette instruction n'est pas suivie exactement, un 

feu, explosion ou production de protoxyde de carbone 

peut résulter le dommages causer de propriété, perte 

ou blessure personnelle de vie.  L'agence qualifiée de 

service est esponsable de l'installation propre de cet 

équipment.  L'installation n'est pas propre et compléte 

jusqu'à l'opération de l'appareil converti est chéque 

suivant les critères établis dans les instructions de 

propriétaire provisionnées avec l'équipement.

         IMPORTaNT

The burner orifices provided in this kit are only for 

use at elevations of 0 to 2,000 feet (610 M) in the 

uSa and 0 to 4,500 feet (0-1372 M) in Canada.  at 

higher elevations the BTu input must be de-rated 

by 4% for every 1,000 feet (305 M) to maintain 

the proper ratio of gas to air.  If the installer must 

convert the unit to adjust for varying altitudes, a 

deration information sticker must be filled out by the 

installer and adhered to the appliance at the time 

of the conversion. Contact your local gas supplier 

for deration requirements for your area. 

DR

AF

T

8/1

5/2

00

8

A

B

Fig. 2

Figure 1 - Kit Contents

Figure 2 - Tools Needed

C

1

Summary of Contents for Elite Series DBv-CK-LP TO NG

Page 1: ...nciales ayant juridiction et conformément aux exigences du code d installation CAN CSA B149 1 IMPORTANT CANADA Theconversionshallbecarriedoutinaccordancewith therequirementsoftheprovincialauthoritieshaving jurisdictionandinaccordancewiththerequirements of the CAN CSA B149 1 Installation code AVERTISSEMENT Cet équipement de conversion sera installé par une agencequalifiéedeserviceconformémentauxins...

Page 2: ...he new screws supplied with this kit Locate the label provided in the regulator kit Write in the required information then affix it to the valve Fill out affix label from regulator kit to valve Remove These Screws Regulator Gas Valve located in control com partment below firebox Figure 3 Replace Regulator on Valve Step 3 Using a 5 32 allen wrench remove the glass door by first loosening the three ...

Page 3: ... remove burner unscrew the 5 32 allen head screw securing the right end of the burner See Figure 8 Step 7 Next push the air shutter control lever in until it stops See Figure 9 Step 8 Slide burner to the right until it comes off the burner orifice Lift the right end of burner until it releases from the copper rod See Figure 10 Remove 5 32 allen head screw Figure 9 Push In Shutter Lever Push air sh...

Page 4: ...Transparent Yellow Flame Blue Flame Center Ports on Pan Burner Assembly Figure 16 Proper Pilot Flame Appearance Inlet Gas Supply Pressure Fuel Minimum Maximum Desired Nat Gas 5 WC po C E 1 24 kPa 10 5 WC po C E 2 61 kPa 7 WC po C E 1 74 kPa Manifold Gas Supply Pressure Fuel Low High Natural Gas Lo 1 7 WC po C E 0 42 kPa Hi 3 5 WC po C E 0 87 kPa Step 11 Install burner and make sure air shutter is ...

Reviews: