14
54D0700
FP1991
remove screws
FP1993
replace flue pipe
FP1992
remove flue pipe
BDV Series Gas Fireplace
VENt INStALLAtION
OptIONAL tOp VENt AppLIcAtION
The appliance is shipped as a rear vent unit. If the instal-
lation layout requires the unit to be a top vent configu-
ration the appliance can be converted by following the
steps below.
When removing and refitting the plates and adapter be
sure the associated gaskets are undamaged and refitted
as required.
1. Remove the eight (8) screws securing the flue pipe
adapter to the fireplace body.
Figure 8
2. Set the flue pipe adapter aside, complete with the
gasket. Do not damage the gaskets as the adapter
and gasket must be refitted.
3. Remove the eight (8) screws securing the flue pipe
cover to the top of the intake box and remove the
cover and gasket.
Figure 8
4. Remove the six (6) screws securing the flue pipe to
the back of the intake box and remove the pipe and
gasket.
Figure 9
5. Replace flue pipe to top of firebox. Ensure the gasket
is in place and undamaged. Secure with six (6)
screws.
Figure 10
6. Place the flue pipe cover and gasket removed in Step
3 over the flue opening in back of the intake box.
7. Refit the flue pipe adapter and gasket to the top of
fireplace. Secure the adapter with eight (8) screws
removed in step 1.
After conversion to top vent
configuration the 4" (100mm) flue pipe
should be concentric within the 6
5
/
8
"
(175mm) outer collar (within
1
/
4
").
W
ARNING
Figure 8 - Removing sixteen (16) Screws from Flue
Pipe Adapter and Flue Pipe Cover
Figure 9 - Removing Flue Pipe
Figure 10 - Attaching Flue Pipe to Top
Vent Configurations
Screws
Flue Pipe
Cover
Flue Pipe
Adapter
Flue Pipe
Screws
Flue Cover
Flue Pipe
Screws
FP1991
FP1992
FP1993