set the parameters. Then press the right arrow. The size of the circles and
the direction of travel is irrelevant.
5. The icon in the upper right should flash “
<-ADJUST->
” along with
“
BRAC
” on the lower left.
6. Press the right arrow again to proceed to the next step.
7. The word “
CAL
”should be in the lower left box with “
TURN TWICE
”
flashing in the upper right.
8. Once again make two complete circle in less than two minutes.
9. Press the
RIGHT
arrow button one last time to complete the calibration
procedures.
More detailed information with cautions and warnings can be found
in the manufacturer’s manual, located in the owner information file
box.
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
The exhaust fan is controlled by a wall
thermostat and is powered with 12 Volt DC.
To operate the fan, remove the ceiling grill
cover, open the grill dampers and select one of
three fan speeds with the round knob on the
grill. Set the thermostat to the
ON
setting for
continuous air flow or to
AUTO
and the
desired air temperature for the On/Off air
flow. To turn the fan off, set the thermostat to
the
OFF
setting, close the grill dampers and
reinstall the ceiling grill cover.
NOTE: Close the grill dampers before installing the grill cover.
Failure to close the damper will result in the cover blowing off while
the motorhome is moving.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
The fan is a three speed fan with a
0
or
OFF
position. The fan has a built in
thermostat, with the operating range within 22º F to 123º F. This range of
operation is based on the INSIDE ambient air temperature. This is the dark blue
to dark red dial on the fan unit. The fan lid is electrically controlled during
normal operations. It can be manually operated by the crank handle and thumb
switch located on the fan. The thumb switch should be snapped back in the
AUTO
position immediately after using the
MANUAL
position. Once the lid
opens approximately two inches, the fan motor will operate.
Appliance & Equipment
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
E X E C U T I V E
3 • 8 9
GALLEY & BATHROOM FANS
Galley Exhaust Fan
Bathroom Fan
Wall Thermostat.
Содержание Executive 2001
Страница 1: ......
Страница 6: ...E X E C U T I V E SECTION 1 WARRANTY INFORMATION...
Страница 7: ......
Страница 22: ...E X E C U T I V E SECTION 2 OPERATING SAFETY...
Страница 23: ......
Страница 46: ...E X E C U T I V E SECTION 3 APPLIANCES EQUIPMENT...
Страница 47: ......
Страница 106: ...E X E C U T I V E CHAPTER 4 WATER LP GAS SYSTEMS...
Страница 107: ......
Страница 129: ...Water LP Gas Systems EXECUTIVE 4 1 2 9 NOTES...
Страница 130: ...E X E C U T I V E SECTION 5 ELECTRICAL SYSTEMS...
Страница 131: ......
Страница 177: ...Electrical Systems 5 1 7 7 EXECUTIVE N NO OT TE ES S...
Страница 178: ...E X E C U T I V E SECTION 6 UNIT CARE MAINTENANCE...
Страница 179: ......
Страница 203: ...Unit Care Maintenance EXECUTIVE 6 2 0 3 NOTES...
Страница 204: ...E X E C U T I V E SECTION 7 CHASSIS INFORMATION...
Страница 205: ......
Страница 264: ...Chassis Information EXECUTIVE 7 2 6 4 NOTES...
Страница 269: ...Chassis Information EXECUTIVE 7 2 6 9 NOTES...