WARNING: Before beginning any service or work on the water
heater make sure the LP-Gas is turned off, the 120 Volt AC source
has been disconnected and the 12 Volt DC source has been
disconnected. Failure to do so can result in explosion, fire or injury.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
• If water heater fails to light, check the outside burner tube for obstructions.
Spiders may make nests in the burner tube.
• If the indicator light on the monitor panel does not light and the water
heater does not light, make sure the battery cut-off switch at the entry door
is on, or check for a blown fuse in the house distribution panel.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
• If the 120 Volt piloted switch at the galley is lit, but there is no hot water,
check the
ON/OFF
switch on the water heater unit.
• If the 120 Volt piloted switch does not light, check the AC source, breaker,
shore cord connection or transfer switch.
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
The Aqua-Hot heat system is specially designed for use in motorhomes. The
Aqua-Hot is an appliance combining a water heater with a furnace. The Aqua-
Hot will provide an almost endless supply of hot water and heat the interior of
the motorhome. A 50,000 BTU diesel fired burner and a 1,650 watt AC element
heats a 50/50 antifreeze solution to approximately 200º Fahrenheit. The
antifreeze solution is pumped through heat exchangers located throughout the
motorhome. Four pumps are used to circulate the antifreeze solution. Three
pumps supply the solution to the interior heat exchangers. The fourth pump
circulates the antifreeze solution through the engine. Fresh water is heated when
pumped through a coil tube inside the aqua hot.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Chlorine bleach or other concentrated chlorine bearing chemicals can cause
failure, if not properly and thoroughly rinsed, to the Aqua-Hot’s Domestic
Water Loop (copper tubing). The Aqua-Hot’s copper tubing is rated for use with
fresh water and winterization solutions only. Periodic flushing with other com-
mon household chemicals including bleach will have little or no effect on the
product if properly rinsed with the fresh water afterwards. Failure of copper
tubing, especially soft or flexible copper, can result if materials other than water
or winterization solutions are allowed to reside inside the piping for extended
periods as during storage or other periods of non-use. The most common cause
for failure is due to an extended exposure to chlorine, solutions containing
chlorine (i.e., bleach), or hydrochloric acid.
NOTE: Aqua Hot must be turned ON before using any heat feature.
Appliance & Equipment
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
E X E C U T I V E
3 • 7 7
Troubleshooting -
LP-Gas Operations
Troubleshooting -
Electric Operations
AQUA-HOT
HEATING & HOT
WATER SYSTEM
(Optional)
Aqua-Hot - Use of
Chlorine Bleach
Содержание Executive 2001
Страница 1: ......
Страница 6: ...E X E C U T I V E SECTION 1 WARRANTY INFORMATION...
Страница 7: ......
Страница 22: ...E X E C U T I V E SECTION 2 OPERATING SAFETY...
Страница 23: ......
Страница 46: ...E X E C U T I V E SECTION 3 APPLIANCES EQUIPMENT...
Страница 47: ......
Страница 106: ...E X E C U T I V E CHAPTER 4 WATER LP GAS SYSTEMS...
Страница 107: ......
Страница 129: ...Water LP Gas Systems EXECUTIVE 4 1 2 9 NOTES...
Страница 130: ...E X E C U T I V E SECTION 5 ELECTRICAL SYSTEMS...
Страница 131: ......
Страница 177: ...Electrical Systems 5 1 7 7 EXECUTIVE N NO OT TE ES S...
Страница 178: ...E X E C U T I V E SECTION 6 UNIT CARE MAINTENANCE...
Страница 179: ......
Страница 203: ...Unit Care Maintenance EXECUTIVE 6 2 0 3 NOTES...
Страница 204: ...E X E C U T I V E SECTION 7 CHASSIS INFORMATION...
Страница 205: ......
Страница 264: ...Chassis Information EXECUTIVE 7 2 6 4 NOTES...
Страница 269: ...Chassis Information EXECUTIVE 7 2 6 9 NOTES...