The furnace will operate when the following conditions have been met:
1. The LP-Gas valve on the LP tank is open and the LP-Gas valve at the
furnace is on.
2. The motorhome’s house batteries are charged.
3. The battery cut-off switch at the entry door is in the
ON
position.
WARNING: IF YOU SMELL GAS extinguish all open flames
and turn off the main gas supply. Liquid propane is a highly
volatile and extremely dangerous gas. It can explode or cause
a fire, which may result in property damage, injury or death.
Propane is a “heavy” gas that can “float” on the floor and
“hide” in corners. Open all windows and doors. Do not touch
any electrical switches. They may cause a spark which can
ignite. Keep all open flames, spark producing devices and
smoking material out of the area. Contact a qualified service
center and have the problem correctly diagnosed and repaired
before resuming operation.
NOTE: The automatic ignition circuit board will attempt to
light the burner three times before the ignition board will go
into “lock-out.” If the burner does not light, the furnace
blower motor will continue to run and the wall thermostat
will have to be cycled off
NOTE: Do not store any items or materials in the furnace
area. Restricted air flow may hamper furnace operation
leading to failure and/or fire hazard.
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
• Select the furnace mode on the Comfort Control using the
MODE
button.
• Select the
AUTO
speed with the Fan button.
• Select the desired temperature with the arrow
UP
and
DOWN
buttons.
NOTE: When washing the exterior of the motorhome, avoid a
direct stream of water into the outside furnace vents. This can
damage the furnace.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
• After storage, the furnace may produce a musty smell during the first
couple of cycles.
• Operating the furnace at an altitude above 5,000 feet reduces the BTU
output due to air/fuel ratio.
• The furnace will periodically need to be serviced by a qualified
technician. If the furnace exhibits unusual symptoms or noises, or has an
unusual odor when operating, have the furnace checked or serviced.
Appliance & Equipment
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
E X E C U T I V E
3 • 7 4
Using the Furnace
Tips
Содержание Executive 2001
Страница 1: ......
Страница 6: ...E X E C U T I V E SECTION 1 WARRANTY INFORMATION...
Страница 7: ......
Страница 22: ...E X E C U T I V E SECTION 2 OPERATING SAFETY...
Страница 23: ......
Страница 46: ...E X E C U T I V E SECTION 3 APPLIANCES EQUIPMENT...
Страница 47: ......
Страница 106: ...E X E C U T I V E CHAPTER 4 WATER LP GAS SYSTEMS...
Страница 107: ......
Страница 129: ...Water LP Gas Systems EXECUTIVE 4 1 2 9 NOTES...
Страница 130: ...E X E C U T I V E SECTION 5 ELECTRICAL SYSTEMS...
Страница 131: ......
Страница 177: ...Electrical Systems 5 1 7 7 EXECUTIVE N NO OT TE ES S...
Страница 178: ...E X E C U T I V E SECTION 6 UNIT CARE MAINTENANCE...
Страница 179: ......
Страница 203: ...Unit Care Maintenance EXECUTIVE 6 2 0 3 NOTES...
Страница 204: ...E X E C U T I V E SECTION 7 CHASSIS INFORMATION...
Страница 205: ......
Страница 264: ...Chassis Information EXECUTIVE 7 2 6 4 NOTES...
Страница 269: ...Chassis Information EXECUTIVE 7 2 6 9 NOTES...