The three point leveling system features a multiple warning system with
flashing light and a bong alarm to alert you of the jack position. The system also
features a remote control panel located next to the driver seat. The torsion stress
is significantly reduced during proper operating procedures. Damage resulting
from improper procedures can range from windshield damage to entry doors
jamming.
The model 35 J-II leveling system pump is located curbside front with easy
access from the generator door. The valve assembly manifold is mounted on the
the pump motor, providing easy access to the manual retract valves. The system
is designed to be self bleeding in the event any component of the hydraulics has
been removed or repaired. Fully extend and retract each jack twice. The remote
rocker switches will operate with a minimum of 7.5 vdc. Optimum requirements
for operating the system are voltages above 9.6 vdc.
The Auto leveling system consist of two primary control components, a trans-
mitter module located in the first storage compartment overhead and the remote
control panel located next to the driver’s seat. The remote control panel is com-
promised of the various retract/extend switches for the jack legs, a switch for
automatic leveling and all retract and the power ON/OFF switch.
NOTE: The leveling system jacks are not designed for use in changing tires.
This can cause problems with the suspension system, frame alignment and
damage to the windshields.
Chassis Information
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
E X E C U T I V E
7 • 2 4 3
LEVELING SYSTEM
-Hydraulic Leveling
System (RVA)
Содержание Executive 2001
Страница 1: ......
Страница 6: ...E X E C U T I V E SECTION 1 WARRANTY INFORMATION...
Страница 7: ......
Страница 22: ...E X E C U T I V E SECTION 2 OPERATING SAFETY...
Страница 23: ......
Страница 46: ...E X E C U T I V E SECTION 3 APPLIANCES EQUIPMENT...
Страница 47: ......
Страница 106: ...E X E C U T I V E CHAPTER 4 WATER LP GAS SYSTEMS...
Страница 107: ......
Страница 129: ...Water LP Gas Systems EXECUTIVE 4 1 2 9 NOTES...
Страница 130: ...E X E C U T I V E SECTION 5 ELECTRICAL SYSTEMS...
Страница 131: ......
Страница 177: ...Electrical Systems 5 1 7 7 EXECUTIVE N NO OT TE ES S...
Страница 178: ...E X E C U T I V E SECTION 6 UNIT CARE MAINTENANCE...
Страница 179: ......
Страница 203: ...Unit Care Maintenance EXECUTIVE 6 2 0 3 NOTES...
Страница 204: ...E X E C U T I V E SECTION 7 CHASSIS INFORMATION...
Страница 205: ......
Страница 264: ...Chassis Information EXECUTIVE 7 2 6 4 NOTES...
Страница 269: ...Chassis Information EXECUTIVE 7 2 6 9 NOTES...