• To fill the grey tank for calibration, water can be poured in the shower
drain until the water level begins to fill the shower base.
• Remove the plugs to access the adjustments. Insert the adjustment tool
for the desired tank. Simultaneously push button for the desired tank
and rotate the adjustment slowly counterclockwise until the light
indication is decreasing. Gently rotate the adjustment back
clockwise until the light indication is at full.
• Repeat procedure as necessary for remaining tanks.
• When the tanks are dumped, verify the calibration of the tanks. They
should read empty.
NOTE: If your domestic batteries are not at full state of charge
your reading will not be accurate.
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Each water supply feed has its own distribution
line which runs from manifold. Water flows in abun-
dance with no fittings behind walls to restrict flow.
Hot water can be delivered more rapidly, and each
water supply line can be shut off individually.
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
The water pump is used to pressurize
the fresh water system when it is not
connected to city water. The water pump
is totally automatic and self-
priming, operating on demand as water
is used. The pressure equalizer tank
relieves the water pump from cycling
when a small amount of water is used.
The water pump is located in a storage
compartment of the motorhome.
WARNING: Before leaving your coach for extended periods of time (i.e.
overnight or longer), be sure that the city water and all water pumps
have been turned off. Damage from neglect will be responsibility of the
owner and not Monaco Coach Corporation.
To operate the water pump, push on switch and watch for the green light to
stay on. The remote switches are located in the bathroom, on the control panel
next to the entrance door and on the outside water control panel.
Do not allow the pump to run when the fresh water supply tank is empty.
Continued operation with a dry tank may open an electrical circuit and/or
damage the water pump.
Water & LP-Gas Systems
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
E X E C U T I V E
4 • 1 0 9
MANABLOC
PLUMBING
MANIFOLD
WATER PUMP
Water Pump.
Water Pump Switch.
1. Manabloc tee handle,
each water line can be
turned off.
Monitor Adjustment Tool.
1
Test Points on Monitor Panel
Содержание Executive 2001
Страница 1: ......
Страница 6: ...E X E C U T I V E SECTION 1 WARRANTY INFORMATION...
Страница 7: ......
Страница 22: ...E X E C U T I V E SECTION 2 OPERATING SAFETY...
Страница 23: ......
Страница 46: ...E X E C U T I V E SECTION 3 APPLIANCES EQUIPMENT...
Страница 47: ......
Страница 106: ...E X E C U T I V E CHAPTER 4 WATER LP GAS SYSTEMS...
Страница 107: ......
Страница 129: ...Water LP Gas Systems EXECUTIVE 4 1 2 9 NOTES...
Страница 130: ...E X E C U T I V E SECTION 5 ELECTRICAL SYSTEMS...
Страница 131: ......
Страница 177: ...Electrical Systems 5 1 7 7 EXECUTIVE N NO OT TE ES S...
Страница 178: ...E X E C U T I V E SECTION 6 UNIT CARE MAINTENANCE...
Страница 179: ......
Страница 203: ...Unit Care Maintenance EXECUTIVE 6 2 0 3 NOTES...
Страница 204: ...E X E C U T I V E SECTION 7 CHASSIS INFORMATION...
Страница 205: ......
Страница 264: ...Chassis Information EXECUTIVE 7 2 6 4 NOTES...
Страница 269: ...Chassis Information EXECUTIVE 7 2 6 9 NOTES...