The detector is equipped with a self-cleaning CO sensor and requires a ten
minute initial warm-up period to clean the sensor element and achieve
stabilization. The green power light should be lit when the power is on. If the
light is not lit, turn off the power and check all wire connections. If the power
is on and the connections are correct but the indicator still does not light, the
detector should be returned for service. Do not attempt to fix the detector your-
self. The indicator light displays a specific color to monitor the conditions as
follows:
•
Green -
indicates an
“ON”
or normal condition. The CO detector has
power and is sensing air for the presence of CO gas. The alarm horn will
not sound.
•
Yellow -
indicates a
“trouble”
or malfunction condition. The alarm horn
will sound and cannot be reset by the TEST/RESET button.
The CO detector is not working properly and must be immediately
replaced or repaired.
•
Red
- indicates an “
alarm condition
.” The detector has sensed the
presence of a hazardous level of carbon monoxide. The alarm horn will
sound continuously until reset by the RESET switch.
-
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
When the alarm sounds, you should have the detector and the motorhome
checked by an authorized service technician as soon as possible. Never discon-
nect a CO detector to silence an annoying alarm. Evacuate the motorhome
immediately when the RED light is lit and the alarm sounds. Do a head count
to check that all persons are accounted for. Call the nearest fire department and
ask them to determine the source of the carbon monoxide. Do not re-enter the
motorhome until it has been aired out and the problem corrected.
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Test the carbon monoxide detector operation after the motorhome has been
in storage, before each trip and at least once a week during use. You can test
the alarm by holding the test button in until the alarm sounds. The alarm will
stop beeping in about 30 seconds.
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Use a vacuum cleaner to remove dust or any other buildup on the detector.
Do not wash. Wipe the detector with a damp cloth and dry it with a towel. Do
not open the detector for cleaning. Do not paint the detector. It is recommend
that the carbon monoxide detector should be replaced every 10 years.
Operating & Safety
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
E X E C U T I V E
2 • 4 0
Operating
Instructions
When the
Alarm Sounds
Testing
the Detector
Cleaning
the Detector
Содержание Executive 2001
Страница 1: ......
Страница 6: ...E X E C U T I V E SECTION 1 WARRANTY INFORMATION...
Страница 7: ......
Страница 22: ...E X E C U T I V E SECTION 2 OPERATING SAFETY...
Страница 23: ......
Страница 46: ...E X E C U T I V E SECTION 3 APPLIANCES EQUIPMENT...
Страница 47: ......
Страница 106: ...E X E C U T I V E CHAPTER 4 WATER LP GAS SYSTEMS...
Страница 107: ......
Страница 129: ...Water LP Gas Systems EXECUTIVE 4 1 2 9 NOTES...
Страница 130: ...E X E C U T I V E SECTION 5 ELECTRICAL SYSTEMS...
Страница 131: ......
Страница 177: ...Electrical Systems 5 1 7 7 EXECUTIVE N NO OT TE ES S...
Страница 178: ...E X E C U T I V E SECTION 6 UNIT CARE MAINTENANCE...
Страница 179: ......
Страница 203: ...Unit Care Maintenance EXECUTIVE 6 2 0 3 NOTES...
Страница 204: ...E X E C U T I V E SECTION 7 CHASSIS INFORMATION...
Страница 205: ......
Страница 264: ...Chassis Information EXECUTIVE 7 2 6 4 NOTES...
Страница 269: ...Chassis Information EXECUTIVE 7 2 6 9 NOTES...