The diesel burner will consume approximately a ½ gallon of diesel per hour
of continuous burner operation. The diesel burner operates on 12 Volt/65 watts.
The circulating pumps operate on 12 Volt/12 watts each. The diesel fired
burner has a fast recovery rate.
To heat the Aqua-Hot from the diesel burner, turn the switch to the
ON
position. The switch will illuminate when it is turned on. Allow 20-30 minutes
for the Aqua-Hot to reach operating temperature before operating heat
exchangers or using hot water.
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
The electric element works well if plugged into 50 amp service. If the
motorhome is plugged into less than 50 amp service, exercise care so the
electric service provided will not be overloaded. Electric operation recovery
rate is slower than the diesel burner. When the switch is turned on a relay will
send power from the 110 Volt AC panel to the electric element in the Aqua-
Hot. Allow two to three hours for the Aqua-Hot to reach operating temperature
when operating from the electric element.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
The Aqua-Hot antifreeze solution is plumbed with the engine cooling
system. This mixing feature allows the Aqua-Hot to heat the antifreeze and
circulate the solution by a pump through the engine. The engine preheat feature
provides easy engine starting on cool mornings. When traveling, the heated
engine coolant may be pumped through the Aqua-Hot system. This will
provide hot water and heat the interior using the exchangers.
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Turn the diesel switch to the
ON
position. The diesel burner will light. Turn
the Engine Preheat to the
ON
position. This activates the engine pump circulat-
ing coolant from the Aqua-Hot through the engine.
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
The heat exchangers are small radiators with 12 Volt DC blower motors.
Current consumption is approximately .25 watt per large heat exchanger. The
small heat exchanger used in a private bath and for the holding tank bay is .10
watt.
NOTE: The HVAC (heating, ventilating, air conditioning)
system will not operate correctly when both comfort controls
and all zones are not in the same mode. DO NOT set control
to display furnace in one zone and cool displayed in another
zone.
Appliance & Equipment
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
E X E C U T I V E
3 • 7 8
Diesel Burner
Electric Heat
Element
Engine Heat
Exchange System
Engine Preheat
Interior Heat
Exchangers
Содержание Executive 2001
Страница 1: ......
Страница 6: ...E X E C U T I V E SECTION 1 WARRANTY INFORMATION...
Страница 7: ......
Страница 22: ...E X E C U T I V E SECTION 2 OPERATING SAFETY...
Страница 23: ......
Страница 46: ...E X E C U T I V E SECTION 3 APPLIANCES EQUIPMENT...
Страница 47: ......
Страница 106: ...E X E C U T I V E CHAPTER 4 WATER LP GAS SYSTEMS...
Страница 107: ......
Страница 129: ...Water LP Gas Systems EXECUTIVE 4 1 2 9 NOTES...
Страница 130: ...E X E C U T I V E SECTION 5 ELECTRICAL SYSTEMS...
Страница 131: ......
Страница 177: ...Electrical Systems 5 1 7 7 EXECUTIVE N NO OT TE ES S...
Страница 178: ...E X E C U T I V E SECTION 6 UNIT CARE MAINTENANCE...
Страница 179: ......
Страница 203: ...Unit Care Maintenance EXECUTIVE 6 2 0 3 NOTES...
Страница 204: ...E X E C U T I V E SECTION 7 CHASSIS INFORMATION...
Страница 205: ......
Страница 264: ...Chassis Information EXECUTIVE 7 2 6 4 NOTES...
Страница 269: ...Chassis Information EXECUTIVE 7 2 6 9 NOTES...