Heat Pump Operation:
Living room comfort control will operate the front roof air conditioner.
• Depress the
MODE
button repeatedly until Heat Pump is displayed.
• Set desired fan speed by depressing the
FAN
button.
• Set desired heating temperature by depressing the
UP
or
DOWN
buttons.
Bedroom comfort control will operate rear roof air conditioner.
• Depress the
MODE
button repeatedly until Heat Pump is displayed.
• Set desired fan speed by depressing the
FAN
button.
• Set desired heating temperature by depressing the
UP
or
DOWN
buttons.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
The return air filters should be cleaned frequently. They are located on the
motorhome ceiling inside the air intake vent covers. Never run the air condi-
tioner without the return air filters in place. This may plug the evaporator core
with dirt and may substantially affect the performance of the air conditioner.
To Clean:
• Remove the vent covers and filters.
• Wash the filters and covers in warm soapy water. Do not use solvents.
• Rinse the filters and cover thoroughly with fresh water and allow them to dry.
• Reinstall the filters and covers.
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
The furnace and its related components are 12 Volt DC operated. It uses
LP-Gas as its fuel source. Electronic circuitry (automatic ignition) is used to
ignite the burner. The furnace uses outside air for the burner combustion, and
exhaust is expelled through the outside vent. Inside air is drawn into the furnace
and blown across the internal heat exchanger. Heated air is then discharged
through ducted hoses which can be run throughout the motorhome. A warm air
discharge is incorporated to heat the motorhome’s holding tanks.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
The furnace operates in the following manner: The wall thermostat sends a
signal to the front roof air conditioner circuit board, which closes a relay.
Closing a relay sends an electrical signal to the furnace to begin the ignition
cycle. There is a small time delay before the blower motor begins. Once the
blower motor attains a predetermined speed, it will close the air prover or sail
switch. The sail switch, which is now closed, sends the electrical signal through
a high temperature protection switch, then to the automatic ignition circuit
board. After the thermostat is satisfied, the gas valve closes and extinguishes the
burner. The blower motor stops approximately 45 seconds later.
Appliance & Equipment
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
E X E C U T I V E
3 • 7 3
Return Air Filters
FURNACE
Operation
Содержание Executive 2001
Страница 1: ......
Страница 6: ...E X E C U T I V E SECTION 1 WARRANTY INFORMATION...
Страница 7: ......
Страница 22: ...E X E C U T I V E SECTION 2 OPERATING SAFETY...
Страница 23: ......
Страница 46: ...E X E C U T I V E SECTION 3 APPLIANCES EQUIPMENT...
Страница 47: ......
Страница 106: ...E X E C U T I V E CHAPTER 4 WATER LP GAS SYSTEMS...
Страница 107: ......
Страница 129: ...Water LP Gas Systems EXECUTIVE 4 1 2 9 NOTES...
Страница 130: ...E X E C U T I V E SECTION 5 ELECTRICAL SYSTEMS...
Страница 131: ......
Страница 177: ...Electrical Systems 5 1 7 7 EXECUTIVE N NO OT TE ES S...
Страница 178: ...E X E C U T I V E SECTION 6 UNIT CARE MAINTENANCE...
Страница 179: ......
Страница 203: ...Unit Care Maintenance EXECUTIVE 6 2 0 3 NOTES...
Страница 204: ...E X E C U T I V E SECTION 7 CHASSIS INFORMATION...
Страница 205: ......
Страница 264: ...Chassis Information EXECUTIVE 7 2 6 4 NOTES...
Страница 269: ...Chassis Information EXECUTIVE 7 2 6 9 NOTES...