Appendix 2C
PU PERFORMANCE C
O
MPARISON
Appendix 2.
1Compar
ison of Q, LCPU w
ith AnN
C
PU, AnACPU, and
AnUCPU
Appendix 2.1.4
Timer comparison
*1:
The Q00J/Q00/Q01CPU can use Z0 to Z9.
The Universal model QCPU/LCPU can use Z0 to Z19.
(1) Cautions on using timers
QCPU, LCPU updates the present value of timers and turns ON/OFF the contacts of them at the execution of OUT T
instruction.
Therefore, if "Present value Set value" when the timer coil is turned ON, the contact of that timer is turned ON.
When creating a program in which the operation of the timer contact triggers the operation of another timer, create the
program for the timer that operates later first.
In the following cases, all timers go ON at the same scan if the program is created in the order the timers operate.
• With high speed timers, if the set value is smaller than a scan time.
• With slow timers, if "1" is set.
Function
QCPU/LCPU
AnUCPU
AnACPU
AnNCPU
Low speed timer
Measurement
unit
100ms (default value)
Change of measurement unit at the parameter is
enabled.
QCPU/LCPU: 1 to 1000ms (1ms unit)
Fixed at 100ms
Designation
method
High speed timer
Measurement
unit
10ms (default value)
Change of measurement unit at the parameter is
enabled.
QnUCPU/LCPU: 0.01 to 100ms (0.01ms unit)
QCPU(Other than QnUCPU)
: 0.1 to 100ms (0.1ms unit)
Fixed at 10ms
Designation
method
High speed timer setting:
Conducted by sequence program
High speed timer setting:
Conducted at parameters
Retentive timers
Measurement
unit
Same measurement unit as low speed timer
Fixed at 100ms
Designation
method
High speed
retentive timer
Measurement
unit
Same measurement unit as high speed timer
None
Designation
method
High speed timer setting:
Conducted by sequence program
Setting range for set values
1 to 32767
1 to 32767
Processing for set value 0
Momentarily ON
No maximum (does not time out)
Index modification
Contact
Enabled (only Z0 and Z1 are usable)
Enabled
Disabled
Coil
Enabled (only Z0 and Z1 are usable)
Disabled
Disabled
Set value
Enabled (Z0 to Z15 are usable)
*1
Disabled
Disabled
Present value Enabled (Z0 to Z15 are usable)
*1
Enabled
Enabled
Update processing for present
value
When OUT Tn instruction is executed
When END processing is done
Contact ON/OFF processing
T
0
K
100
T
0
K
100
T0
H
K100
High speed timer specification
T
200
K
100
S
T
0
K
100
T
0
K
100
ST0
H
K100
High speed timer specification