775
3
2
3
A
5
6
7
8
Appendix 1OPERATI
O
N PR
OCESSING TIME
Appendix 1.
4Oper
ation Processing Ti
me of U
niversal Model QC
P
U
Category Instruction
Condition (Device)
Processing Time (µs)
Q00UJCPU
Q00UCPU
Q01UCPU
Q02UCPU
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Application
instruction
ANDTM<>
When not executed
0.480
0.320
0.240
0.160
Comparison
of specified
clock
In conductive
status
8.200
25.500
8.200
25.500
6.500
25.500
7.000
23.000
In non-conductive
status
8.200
25.500
8.200
25.500
6.500
25.500
7.000
23.000
Comparison
of current
clock
In conductive
status
6.500
23.100
6.500
23.100
6.500
23.100
5.600
21.900
In non-conductive
status
6.500
23.100
6.500
23.100
6.500
23.100
5.600
21.900
ORTM<>
When not executed
0.480
0.320
0.240
0.160
Comparison
of specified
clock
In conductive
status
8.200
25.500
8.200
25.500
6.500
25.500
7.300
23.200
In non-conductive
status
8.200
25.500
8.200
25.500
6.500
25.500
7.300
23.200
Comparison
of current
clock
In conductive
status
6.500
23.100
6.500
23.100
6.500
23.100
5.900
22.000
In non-conductive
status
6.500
23.100
6.500
23.100
6.500
23.100
5.900
22.000
LDTM>
Comparison
of specified
clock
In conductive
status
8.200
25.500
8.200
25.500
6.500
25.500
7.300
23.300
In non-conductive
status
8.200
25.500
8.200
25.500
6.500
25.500
7.300
23.300
Comparison
of current
clock
In conductive
status
6.500
23.100
6.500
23.100
6.500
23.100
5.900
22.100
In non-conductive
status
6.500
23.100
6.500
23.100
6.500
23.100
5.900
22.100
ANDTM>
When not executed
0.480
0.320
0.240
0.160
Comparison
of specified
clock
In conductive
status
8.200
25.500
8.200
25.500
6.500
25.500
7.000
23.000
In non-conductive
status
8.200
25.500
8.200
25.500
6.500
25.500
7.000
23.000
Comparison
of current
clock
In conductive
status
6.500
23.100
6.500
23.100
6.500
23.100
5.600
21.900
In non-conductive
status
6.500
23.100
6.500
23.100
6.500
23.100
5.600
21.900
ORTM>
When not executed
0.480
0.320
0.240
0.160
Comparison
of specified
clock
In conductive
status
8.200
25.500
8.200
25.500
6.500
25.500
7.300
23.200
In non-conductive
status
8.200
25.500
8.200
25.500
6.500
25.500
7.300
23.200
Comparison
of current
clock
In conductive
status
6.500
23.100
6.500
23.100
6.500
23.100
5.900
22.000
In non-conductive
status
6.500
23.100
6.500
23.100
6.500
23.100
5.900
22.000
LDTM<=
Comparison
of specified
clock
In conductive
status
8.200
25.500
8.200
25.500
6.500
25.500
7.300
23.300
In non-conductive
status
8.200
25.500
8.200
25.500
6.500
25.500
7.300
23.300
Comparison
of current
clock
In conductive
status
6.500
23.100
6.500
23.100
6.500
23.100
5.900
22.100
In non-conductive
status
6.500
23.100
6.500
23.100
6.500
23.100
5.900
22.100