781
3
2
3
A
5
6
7
8
Appendix 1OPERATI
O
N PR
OCESSING TIME
Appendix 1.
4Oper
ation Processing Ti
me of U
niversal Model QC
P
U
Category
Instruc-
tion
Condition (Device)
Processing Time (µs)
Q03
UD(E)CPU
Q04/Q06
UD(E)HCPU
Q10/Q13/Q20/
Q26UD(E)HCPU
Q50/Q100
UDEHCPU
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Basic
instruction
ORE>
Single
precision
When not executed
0.060
0.0285
0.0285
0.0285
When
executed
In conductive status
3.600
5.100
3.300
4.600
In non-conductive status
3.500
4.800
3.200
4.500
LDE<=
Single
precision
In conductive status
3.800
5.600
3.400
5.200
0.0285
0.0285
In non-conductive status
3.800
5.600
3.400
5.100
ANDE<=
Single
precision
When not executed
0.060
0.0285
0.0285
0.0285
When
executed
In conductive status
3.200
4.600
2.800
4.200
In non-conductive status
3.500
5.000
3.100
4.500
ORE<=
Single
precision
When not executed
0.060
0.0285
0.0285
0.0285
When
executed
In conductive status
3.700
5.800
3.400
5.400
In non-conductive status
3.800
5.700
3.300
5.300
LDE<
Single
precision
In conductive status
4.000
5.400
3.500
4.900
0.0285
0.0285
In non-conductive status
4.000
5.200
3.500
4.900
ANDE<
Single
precision
When not executed
0.060
0.0285
0.0285
0.0285
When
executed
In conductive status
3.400
4.600
3.000
4.200
In non-conductive status
3.500
4.900
3.100
4.400
ORE<
Single
precision
When not executed
0.060
0.0285
0.0285
0.0285
When
executed
In conductive status
3.600
5.200
3.300
4.900
In non-conductive status
3.400
4.900
3.200
4.500
LDE>=
Single
precision
In conductive status
3.800
6.000
3.300
5.500
0.0285
0.0285
In non-conductive status
3.800
5.900
3.400
5.400
ANDE>=
Single
precision
When not executed
0.060
0.0285
0.0285
0.0285
When
executed
In conductive status
3.200
4.800
2.900
4.600
In non-conductive status
3.500
5.400
3.100
5.100
ORE>=
Single
precision
When not executed
0.060
0.0285
0.0285
0.0285
When
executed
In conductive status
3.600
5.200
3.300
4.700
In non-conductive status
3.500
5.200
3.200
4.700
LDED=
Double
precision
In conductive status
4.100
7.700
3.500
7.200
3.500
7.200
3.500
7.200
In non-conductive status
4.300
8.100
3.800
7.400
3.800
7.400
3.800
7.400
ANDED=
Double
precision
When not executed
0.060
0.0285
0.0285
0.0285
When
executed
In conductive status
3.600
7.600
3.200
7.000
3.200
7.000
3.200
7.000
In non-conductive status
3.900
7.700
3.400
7.400
3.400
7.400
3.400
7.400
ORED=
Double
precision
When not executed
0.060
0.0285
0.0285
0.0285
When
executed
In conductive status
3.800
8.800
3.400
8.300
3.400
8.300
3.400
8.300
In non-conductive status
4.000
9.300
3.700
8.800
3.700
8.800
3.700
8.800
LDED<>
Double
precision
In conductive status
4.400
8.200
3.900
7.700
3.900
7.700
3.900
7.700
In non-conductive status
4.100
7.900
3.500
7.500
3.500
7.500
3.500
7.500
ANDED<>
Double
precision
When not executed
0.060
0.0285
0.0285
0.0285
When
executed
In conductive status
3.800
7.600
3.300
7.200
3.300
7.200
3.300
7.200
In non-conductive status
3.800
7.700
3.400
7.300
3.400
7.300
3.400
7.300
ORED<>
Double
precision
When not executed
0.060
0.0285
0.0285
0.0285
When
executed
In conductive status
4.100
9.300
3.700
8.900
3.700
8.900
3.700
8.900
In non-conductive status
3.800
8.900
3.400
8.400
3.400
8.400
3.400
8.400
LDED>
Double
precision
In conductive status
4.300
8.100
3.800
7.500
3.800
7.500
3.800
7.500
In non-conductive status
4.100
7.800
3.500
7.200
3.500
7.200
3.500
7.200
ANDED>
Double
precision
When not executed
0.060
0.0285
0.0285
0.0285
When
executed
In conductive status
3.800
7.700
3.300
7.300
3.300
7.300
3.300
7.300
In non-conductive status
4.000
7.900
3.500
7.500
3.500
7.500
3.500
7.500
ORED>
Double
precision
When not executed
0.060
0.0285
0.0285
0.0285
When
executed
In conductive status
4.100
9.300
3.700
8.800
3.700
8.800
3.700
8.800
In non-conductive status
4.100
9.300
3.700
8.800
3.700
8.800
3.700
8.800
LDED<=
Double
precision
In conductive status
4.000
8.000
3.500
7.400
3.500
7.400
3.500
7.400
In non-conductive status
4.100
9.400
3.600
8.800
3.600
8.800
3.600
8.800