• The special function module’s buffer memory contains 16 bits (one word) per
one address and reading/writing operations between the PLC CPU and
intelligent functional module are performed with the FROM/TO instructions.
When reading/writing from the special function module’s buffer memory to the
QD51 (-R24) or vice versa, the operation is performed in units of 8 bits (one
byte) per one address.
The addresses (hexadecimal) to specify in the QD51 (-R24) are obtained by the
following conversion from addresses for the FROM/TO instructions.
Specified address (hexadecimal) = convert {(address for the FROM/TO instruction x 2)} into a hexadecimal
number, then add (the starting address of each module)
Example: When specifying address 1 of the FROM/TO instructions (the preset
value of CH.1) of the type AD61 high-speed counter module.
Specified
address 82
H
FROM/TO instruction
address 0
×
2, 1
H
×
2
starting
address 80
H
=
+
See Appendix for the starting address of each intelligent functional module.
• Assign values to %(3) and %(4) ( %(6) and %(7) in case of a format 2
control table, %(7) and %(8) in case of a format 3 control table) in the
following manner.
D!
H!
L!
H&
L$
• • • • • • The specified address calculated using the formula above
• • • • • • Used as work areas.
to
100
110
120
130
140
150
to
H!=INT(D!/65536!)
L!=D!-H!*65536!
H$=RIGHT$(“0000”+HEX$(H!))
L$=RIGHT$(“0000”+HEX$(L!))
%(3)=VAL(“&H”+L$) • • • • • • • • • •
%(4)=VAL(“&H”+H$) • • • • • • • • • •
In case of a format 2 control table
%(6)=VAL(“&H”+L$)
%(7)=VAL(“&H”+H$)
Содержание A1SD51S
Страница 183: ...11 13 11 13 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS RUN Before swap A 0 H924 A 1 H1159 After swap A 0 H1159 A 1 H924 OK...
Страница 331: ...11 161 11 161 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS REMARK See the CON ON OFF STOP and ZOPEN functions and Section 7 4...
Страница 557: ...11 387 11 387 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS REMARK See the CHR SPACE and SPC functions...
Страница 629: ...11 459 11 459 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS REMARK See the ZOPEN ZSEND and ZCNTL instructions and Section 7 3 4...
Страница 645: ...11 475 11 475 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS REMARK See the ZEVENT ZSIGNAL and DEF ZEVENT instructions...