11 - 336 11 - 336
MELSEC-Q
11 INSTRUCTIONS AND FUNCTIONS
Format 1 control table
%(0)
• • • • • •
Specify the station number of the PLC CPU to which data is
written.
See Section 4.2.2 for the allowable specification range.
%(1)
• • • • • •
Processing code
• Specify 533 (&H215).
%(2)
• • • • • •
Specify the starting I/O number of the intelligent functional
module to whose buffer memory data is to be written.
%(3)
• • • • • •
Specify the address (lower) of buffer memory to which data
is to be written.
%(4)
• • • • • •
Specify the address (higher) of buffer memory to which
data is to be written.
%(5)
• • • • • •
Specify the number of bytes of data to be written, including
the specified intelligent functional module’s buffer memory
address.
The allowable specification range is as follows:
• Q series CPU
• QnA series CPU
1 to 1920 bytes
1 to 960 bytes
Format 2 control table
%(0)
• • • • • •
Format 2 control table
• Specify 256 (&H100).
%(1)
• • • • • •
Specify the network number of the network to be accessed.
See Section 4.2.2 for the allowable specification range.
%(2)
• • • • • •
Specify the station number of the PLC CPU to which data is
written.
See Section 4.2.2 for the allowable specification range.
%(3)
• • • • • •
Detailed error codes are stored here.
See Appendix 4.4.2 for the details about the error codes.
%(4)
• • • • • •
Processing code
• Specify 533 (&H215).
%(5)
• • • • • •
Specify the starting I/O number of the intelligent functional
module to whose buffer memory data is to be written.
%(6)
• • • • • •
Specify the address (lower) of buffer memory to which data
is to be written.
%(7)
• • • • • •
Specify the address (higher) of buffer memory to which
data is to be written.
%(8)
• • • • • •
Specify the number of bytes of data to be written, including
the specified intelligent functional module’s buffer memory
address.
The allowable specification range is as follows:
• Q series CPU
• QnA series CPU
1 to 1920 bytes
1 to 960 bytes
Содержание A1SD51S
Страница 183: ...11 13 11 13 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS RUN Before swap A 0 H924 A 1 H1159 After swap A 0 H1159 A 1 H924 OK...
Страница 331: ...11 161 11 161 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS REMARK See the CON ON OFF STOP and ZOPEN functions and Section 7 4...
Страница 557: ...11 387 11 387 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS REMARK See the CHR SPACE and SPC functions...
Страница 629: ...11 459 11 459 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS REMARK See the ZOPEN ZSEND and ZCNTL instructions and Section 7 3 4...
Страница 645: ...11 475 11 475 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS REMARK See the ZEVENT ZSIGNAL and DEF ZEVENT instructions...