11 - 307 11 - 307
MELSEC-Q
11 INSTRUCTIONS AND FUNCTIONS
(f) Module number of the special function module of a MELSECNET/10 remote I/O
station
The module number of the special function module of a MELSECNET/10 remote
I/O station is always the two higher digits of the 3-digit expression of the last "I/O
address seen from a remote I/O station."
Specify the module number using the last "I/O address seen from a remote I/O
station" regardless of the settings of the common parameters set at the master
station of the MELSECNET/10 remote I/O net.
S
peci
a
l f
unct
ion
m
odul
e
32
poi
nt
s
Since the last address is 44F
H
,
the special function module number is "44
H
."
O
u
tput
m
odul
e 3
2
poi
n
ts
O
u
tput
m
odul
e 3
2
poi
n
ts
O
u
tput
m
odul
e 1
6
poi
n
ts
O
u
tput
m
odul
e 3
2
poi
n
ts
P
o
wer suppl
y
m
odul
e
Remote I/O
station No.1
Y
470
48F
Y
450
46F
X/Y
430
44F
Y
420
42F
Y
400
41F
Y
70
8F
Y
50
6F
X/Y
30
4F
Y
20
2F
Y
00
1F
I/O addresses seen from
a remote I/O station
I/O addresses set by
the common parameters
A
J
72LP
25
to
to
to
to
to
to
to
to
to
to
• The special function module's buffer memory contains 16 bits (one word) per address
and reading/writing operations between the PLC CPU and special function module
are performed using the FROM/TO instructions. When reading/writing from the
special function module's buffer memory to the communication module or vice versa,
the operation is performed in units of 8 bits (1 byte) per address.
The addresses to specify in the communication module (hexadecimal) are obtained
by the following conversion from addresses for the FROM/TO instructions.
Specified address
(hexadecimal)
the starting address
of each module
= convert
(address for the
FROM/TO
instruction x 2)
into a hexadecimal
number
+
[
]
{
}
Example : When specifying address 1 of the FROM/TO instruction (the preset value of
CH.1) of the type AD61 high-speed counter module.
Specified
address 82
H
FROM/TO instruction
address 0
×
2, 1
H
×
2
starting
address 80
H
=
+
See Appendix for the head address of each special function module
Содержание A1SD51S
Страница 183: ...11 13 11 13 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS RUN Before swap A 0 H924 A 1 H1159 After swap A 0 H1159 A 1 H924 OK...
Страница 331: ...11 161 11 161 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS REMARK See the CON ON OFF STOP and ZOPEN functions and Section 7 4...
Страница 557: ...11 387 11 387 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS REMARK See the CHR SPACE and SPC functions...
Страница 629: ...11 459 11 459 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS REMARK See the ZOPEN ZSEND and ZCNTL instructions and Section 7 3 4...
Страница 645: ...11 475 11 475 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS REMARK See the ZEVENT ZSIGNAL and DEF ZEVENT instructions...