11 - 276 11 - 276
MELSEC-Q
11 INSTRUCTIONS AND FUNCTIONS
Program Example
(1) Program example for a format 1 control table
100 ' A program example that monitors extension file registers registered to be monitored by the
PCWT instruction
110 DINM TBL1%(10),A%(20),TBL2%(10),B%(20)
:
'Defines arrays
120 TBL1%(0)=255
:
'Specifies the station number to
communicate with to the local station
130 TBL1%(1)=5
:
'Specifies to register extension file registers
to be monitored
140 TBL1%(2)=2
:
'Specifies the number of points to be
monitored
150 A%(0)=1:A%(1)=0
:
'Specifies block number 1 and device
number 0
160 A%(2)=1:A%(3)=1
:
'Specifies block number 1 and device
number 1
170 PCWT TBL1%( ),A%( )
:
'Executes the monitor registration
180 TBL2%(0)=255
:
'Specifies the station number to
communicate with to the local station
190 TBL2%(1)=5
:
'Specifies to monitor extension file registers
200 PCRD TBL2%( ),B%( )
:
'Executes the monitoring
210 PRINT"B%(0)=" :B%(0)
:
Displays the result
220 PRINT"B%(1)=" :B%(1)
230 END
Содержание A1SD51S
Страница 183: ...11 13 11 13 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS RUN Before swap A 0 H924 A 1 H1159 After swap A 0 H1159 A 1 H924 OK...
Страница 331: ...11 161 11 161 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS REMARK See the CON ON OFF STOP and ZOPEN functions and Section 7 4...
Страница 557: ...11 387 11 387 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS REMARK See the CHR SPACE and SPC functions...
Страница 629: ...11 459 11 459 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS REMARK See the ZOPEN ZSEND and ZCNTL instructions and Section 7 3 4...
Страница 645: ...11 475 11 475 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS REMARK See the ZEVENT ZSIGNAL and DEF ZEVENT instructions...