11 - 32 11 - 32
MELSEC-Q
11 INSTRUCTIONS AND FUNCTIONS
CONSOLE
Instruction
CONSOLE
• Sets the number of display lines of the console screen.
CONSOLE <number of lines>
Syntax
number of lines
• • • •
Specify the number of display lines as 20 through 32
depending on the console used.
Examples
CONSOLE 25
• • • •
Displays 25 lines.
Description
• The CONSOLE instruction sets the number of display lines of the console according to the
console screen.
• The initial condition of the CONSOLE instruction is set according to the console set by
MODE SW2.
• The following values are used when VG-620, VT-382, and A7PHP are used:
VG-620
VT-382
IBM/AT compatible, PC-9800, A7PHP, A7LMS
• • • •
• • • •
• • • •
24 lines
24 lines
25 lines
• Normal screen scroll operation is not performed if the specified number of lines differs from
the number of display lines of the console.