App - 30 App - 30
MELSEC-Q
APPENDIX
Appendix 7.2.2 RS (RTS) control enabled
When the RS (RTS) control is enabled, RS (RTS) control signals of the target interface
are turned ON/OFF based on the size of the free area in the receive buffer specified by
the user, allowing the data transmission from the external device to the communication
module to be controlled and requested.
An RS (RTS) control signal is turned OFF when the free area in the receive buffer
becomes one-fourth or less of the total space as data received from the external
device is stored.
An RS (RTS) control signal is turned ON when the free area in the receive buffer
becomes three-fourths or more of the total space because of receive requests from the
BASIC program in the communication module.
A
D51H
(BASIC program)
ZOPEN • • • •
ZRECEIVE • • • •
Data
reception result
ZRECEIVE • • • •
Data
reception result
Data
reception result
ZRECEIVE • • • •
Communication module
Channel open 1
Receive buffer
(OS)
2
External device
The free area is
one-fourth or less.
The free area is
three-fourths or more.
Data
Data
RS control
signal
OFF
RS control
signal
ON
RS control
signal
ON
3
ZCLOSE
Содержание A1SD51S
Страница 183: ...11 13 11 13 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS RUN Before swap A 0 H924 A 1 H1159 After swap A 0 H1159 A 1 H924 OK...
Страница 331: ...11 161 11 161 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS REMARK See the CON ON OFF STOP and ZOPEN functions and Section 7 4...
Страница 557: ...11 387 11 387 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS REMARK See the CHR SPACE and SPC functions...
Страница 629: ...11 459 11 459 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS REMARK See the ZOPEN ZSEND and ZCNTL instructions and Section 7 3 4...
Страница 645: ...11 475 11 475 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS REMARK See the ZEVENT ZSIGNAL and DEF ZEVENT instructions...