11 - 234 11 - 234
MELSEC-Q
11 INSTRUCTIONS AND FUNCTIONS
(3) Program example a for format 3 control table
100 'A program example that reads the device memory of the Q/QnA series CPU
110 DIM TBL%(10),A%(100)
:
'Defines the arrays
120 TBL%(0)=257
:
'Specifies a format 3 control table
130 TBL%(1)=1
:
'Specifies network number 1
140 TBL%(2)=1
:
'Specifies station number 1
150 TBL%(4)=515
:
'Specifies to read device memory of the
Q/QnA series CPU
160 TBL%(5)=&H03E3
:
'Specifies the requested CPU (PLC No.4)
170 TBL%(5)=144
:
'Specifies internal relays M
180 D!=0
:
'Specifies device number 0
190 H!=INT(D!/65536!)
:
'Splits into lower and higher digits
200 L!=D!-H!*65536!
210 H$=RIGHT$("0000"+HEX$(H!),4)
220 L$=RIGHT$("0000"+HEX$(L!),4)
230 TBL%(6)=VAL("&H"+L$)
:
'Stores the lower digit of the device number
240 TBL%(7)=VAL("&H"+H$)
:
'Stores the higher digit of the device
number
250 TBL%(8)=10
:
'Specifies the number of points to be read
260 PCRD TBL%(),A%()
:
'Executes the read operation
270 I=0
280 FOR I=0 TO 100
290 PRINT HEX$(A%(I))
300 NEXT I
310 END
Содержание A1SD51S
Страница 183: ...11 13 11 13 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS RUN Before swap A 0 H924 A 1 H1159 After swap A 0 H1159 A 1 H924 OK...
Страница 331: ...11 161 11 161 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS REMARK See the CON ON OFF STOP and ZOPEN functions and Section 7 4...
Страница 557: ...11 387 11 387 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS REMARK See the CHR SPACE and SPC functions...
Страница 629: ...11 459 11 459 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS REMARK See the ZOPEN ZSEND and ZCNTL instructions and Section 7 3 4...
Страница 645: ...11 475 11 475 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS REMARK See the ZEVENT ZSIGNAL and DEF ZEVENT instructions...