11 - 107 11 - 107
MELSEC-Q
11 INSTRUCTIONS AND FUNCTIONS
• Specify the file name and identifier of the file to be deleted in <file name>. The identifier
cannot be omitted in the KILL instruction.
• The KILL instruction cannot be executed when at least one data file is open. A “File already
open” error occurs when the KILL instruction is executed while a file is open.
REMARK
See Section 3.4.3.
Содержание A1SD51S
Страница 183: ...11 13 11 13 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS RUN Before swap A 0 H924 A 1 H1159 After swap A 0 H1159 A 1 H924 OK...
Страница 331: ...11 161 11 161 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS REMARK See the CON ON OFF STOP and ZOPEN functions and Section 7 4...
Страница 557: ...11 387 11 387 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS REMARK See the CHR SPACE and SPC functions...
Страница 629: ...11 459 11 459 MELSEC Q 11 INSTRUCTIONS AND FUNCTIONS REMARK See the ZOPEN ZSEND and ZCNTL instructions and Section 7 3 4...