338
Appendix 2-1 SERIAL number check
Check the SERIAL number indicated on the inverter rating plate or package.
Appendix 2-2 Changed Functions
(1) Pr. 0 Torque boost, Pr. 12 DC injection brake operation voltage, Pr. 57 Restart coasting time
Available with the inverter having the following serial number or later.
•
Initial value of
Pr. 0 Torque boost
and
Pr. 12 DC injection brake operation voltage
•
Automatic restart after instantaneous power failure operation
Coasting time when
Pr. 57 Restart coasting time
= "0"
Appendix 2 Specification change
Rating plate example
Symbol Year Month Control number
SERIAL (Serial No.)
The SERIAL consists of 1 version symbol, 2 numeric characters
or 1 numeric character and 1 alphabet letter indicating year and
month, and 6 numeric characters indicating control number.
Last digit of the production year is indicated as the Year, and the
Month is indicated by 1 to 9, X (October), Y (November), and Z
(December).
Type
SERIAL (Serial No.)
FR-E720-0.1K to 3.7K
B
FR-E720-5.5K
C
FR-E720-7.5K
D
<
Conventional Type
>
<
New Type
>
PARAMETERS
Name
Initial Value
Initial Value
0
Torque boost
6%
6/4/3%
∗1
12
DC injection brake
operation voltage
6%
6/4%
∗2
∗1
Differ according to capacities. (0.1K to 0.75K / 1.5K to 3.7K / 5.5K, 7.5K)
∗2
Differ according to capacities. (0.1K, 0.2K / 0.4K to 7.5K)
<
Conventional Type
>
<
New Type
>
PARAMETERS
Name
Setting
range
Description
Description
57
Restart coasting
time
0
1.5K or less....................... 0.5s
2.2K to 7.5K................... 1s
of coasting time
1.5K or less....................... 1s
2.2K to 7.5K................... 2s
of coasting time
Содержание FR-E710W-0.1K
Страница 49: ...40 MEMO ...
Страница 65: ...56 MEMO ...
Страница 288: ...288 MEMO ...
Страница 310: ...310 MEMO ...
Страница 334: ...334 MEMO ...
Страница 335: ...335 APPENDIX This chapter provides the APPENDIX of this product Always read the instructions before using the equipment ...
Страница 348: ...4 4 BCN C22005 679 MEMO BCN C22005 679 fm 4 ページ 2014年11月7日 金曜日 午前11時58分 ...