FR-E500 series operation panel (PA02) setting
z
Method to adjust any point without turning the potentiometer (changing from 4V(80%) to 5V(100%))
z
Method to adjust only the gain frequency and not to adjust the voltage
Operation
1.
Perform steps 1. to 4. on page
2.
Set the gain voltage (%).
3.
Pressing
shifts to the next parameter.
4.
Re-set the
Pr.79 Operation mode selection
value according to the operation mode being used.
Operation
1.
Perform steps 1. to 4. on page
2.
Adjust the analog voltage adjustment value.
3.
Pressing
shifts to the next parameter.
4.
Re-set the
Pr. 79 Operation mode selection
value according to the operation mode being used.
CAUTION
Be cautious when setting any value other than "0" as the bias speed at 0V. Even if a speed command is not
given, merely turning ON the start signal will start the motor at the preset frequency.
PU
MON
Hz RUN
A MON
SET
/
Analog voltage
value (%) of the
built-in frequency
setting potentiometer
Press the or
key once to display
the current analog
voltage calibration value.
/
Set the gain voltage (%) with
the key.
[0(%) for 0V (0mA), 100(%) for
5V (10V, 20mA)]
Press for 1.5s
Flicker
PU
MON
Hz RUN
A MON
SET
Analog voltage value (%)
of the built-in frequency
setting potentiometer
Press the or key once to display
the current analog voltage adjustment.
Example:When analog voltage
adjustment value is 100%
Press for 1.5s
Flicker
Содержание FR-E710W-0.1K
Страница 49: ...40 MEMO ...
Страница 65: ...56 MEMO ...
Страница 288: ...288 MEMO ...
Страница 310: ...310 MEMO ...
Страница 334: ...334 MEMO ...
Страница 335: ...335 APPENDIX This chapter provides the APPENDIX of this product Always read the instructions before using the equipment ...
Страница 348: ...4 4 BCN C22005 679 MEMO BCN C22005 679 fm 4 ページ 2014年11月7日 金曜日 午前11時58分 ...