Special operation and frequency control
(1) Dancer control block diagram
∗1
The main speed can be selected from all operation mode such as external (analog voltage input, multi-speed), PU (digital frequency setting), communication
(RS-485, CC-Link).
Set point and measured value of PID control
Input
Input Signal
Pr.267
Setting
Current/Voltage Input Switch
Standard
control circuit
terminal model
Safety stop
function model
Set point
Pr. 133
0 to 100%
—
—
Measured
value
When measured value is input as current
(4 to 20mA)
4mA
.....
0%, 20mA .. 100%
0
When measured value is input as voltage
(0 to
±
5V or 0 to
±
10V)
0V
.........
0%, 5V ........ 100%
1
0V .......... 0%, 10V....... 100%
2
NOTE
Changing the terminal function using any of
Pr. 178 to Pr. 184
may affect the other functions. Set parameters after
confirming the function of each terminal.
When the
Pr. 267
setting was changed, check the voltage/current input switch setting. Different setting may cause a
fault, failure or malfunction. (
for setting)
Limit
Ratio
Acceleration/deceleration
of main speed
Main speed command
*1
Terminal 4
Potentiometer
Pr. 128
= 42, 43
Pr. 128
= 40, 41
Dancer roll position detection
PID control
PID deviation
PID feedback
PID set point
Target frequency
X14
Acceleration/
deceleration
+
+
-
+
Kp(1+
Convert to 0 to 100%
IM
Dancer roll
setting point
Pr. 133
Ti S
1
+
Td S)
Содержание FR-E710W-0.1K
Страница 49: ...40 MEMO ...
Страница 65: ...56 MEMO ...
Страница 288: ...288 MEMO ...
Страница 310: ...310 MEMO ...
Страница 334: ...334 MEMO ...
Страница 335: ...335 APPENDIX This chapter provides the APPENDIX of this product Always read the instructions before using the equipment ...
Страница 348: ...4 4 BCN C22005 679 MEMO BCN C22005 679 fm 4 ページ 2014年11月7日 金曜日 午前11時58分 ...