Deleted functions
Pr. 98
Automatic torque boost selection
Pr. 99
Motor primary resistance
Replacement function (General-purpose magnetic flux
vector control)
(Pr. 80 Motor capacity)
(Pr. 90 Motor constant (R1))
Long wiring mode (setting value 10, 11 of
Pr. 70
)
Setting unnecessary (setting value 10, 11 of
Pr. 240
is
deleted)
Changed parameter
number and name
Parameter
Number
Name
Parameter
Number
Name
Pr. 17
RUN key rotation direction selection
Pr. 40
RUN key rotation direction selection
Pr. 21
Stall prevention function selection
Pr. 156
Stall prevention operation selection
Pr. 28
Stall prevention operation reduction
starting frequency
Pr. 66
Stall prevention operation reduction
starting frequency
Pr. 30
Extended function display selection
Pr. 160
Extended function display selection
Pr. 38
Frequency setting voltage gain frequency
Pr. 125
Terminal 2 frequency setting gain
frequency
Pr. 39
Frequency setting current gain frequency
Pr. 126
Terminal 4 frequency setting gain
frequency
Pr. 40
Start-time ground fault detection selection
Pr. 249
Earth (ground) fault detection at start
Pr. 48
Output current detection level
Pr. 150
Output current detection level
Pr. 49
Output current detection signal delay time Pr. 151
Output current detection signal delay time
Pr. 50
Zero current detection level
Pr. 152
Zero current detection level
Pr. 51
Zero current detection time
Pr. 153
Zero current detection time
Pr. 53
Frequency setting operation selection
Pr. 161
Frequency setting/key lock operation
selection
Pr. 60
RL terminal function selection
Pr. 180
RL terminal function selection
Pr. 61
RM terminal function selection
Pr. 181
RM terminal function selection
Pr. 62
RH terminal function selection
Pr. 182
RH terminal function selection
Pr. 63
STR terminal function selection
Pr. 179
STR terminal function selection
Pr. 64
RUN terminal function selection
Pr. 190
RUN terminal function selection
Pr. 65
A, B, C terminal function selection
Pr. 192
A,B,C terminal function selection
Pr. 66
Retry selection
Pr. 65
Retry selection
Pr. 70
Soft-PWM setting
Pr. 240
Soft-PWM operation selection
Pr. 76
Cooling fan operation selection
Pr. 244
Cooling fan operation selection
Pr. 80
Multi-speed setting (speed 8)
Pr. 232
Multi-speed setting (speed 8)
Pr. 81
Multi-speed setting (speed 9)
Pr. 233
Multi-speed setting (speed 9)
Pr. 82
Multi-speed setting (speed 10)
Pr. 234
Multi-speed setting (speed 10)
Pr. 83
Multi-speed setting (speed 11)
Pr. 235
Multi-speed setting (speed 11)
Pr. 84
Multi-speed setting (speed 12)
Pr. 236
Multi-speed setting (speed 12)
Pr. 85
Multi-speed setting (speed 13)
Pr. 237
Multi-speed setting (speed 13)
Pr. 86
Multi-speed setting (speed 14)
Pr. 238
Multi-speed setting (speed 14)
Pr. 87
Multi-speed setting (speed 15)
Pr. 239
Multi-speed setting (speed 15)
Pr. 88
PID action selection
Pr. 128
PID action selection
Pr. 89
PID proportional band
Pr. 129
PID proportional band
Pr. 90
PID integral time
Pr. 130
PID integral time
Pr. 91
PID upper limit
Pr. 131
PID upper limit
Pr. 92
PID lower limit
Pr. 132
PID lower limit
Pr. 93
PID action set point for PU operation
Pr. 133
PID action set point
Pr. 94
PID differential time
Pr. 134
PID differential time
Pr. 95
Rated motor slip
Pr. 245
Rated slip
Pr. 96
Slip compensation time constant
Pr. 246
Slip compensation time constant
Pr. 97
Constant power range slip compensation
selection
Pr. 247
Constant-power range slip compensation
selection
H7(Pr. 559) Second electronic thermal O/L relay
Pr. 51
Second electronic thermal O/L relay
b1(Pr. 560)
Regenerative function selection
Pr. 30
Regenerative function selection
b2(Pr. 561)
Special regenerative brake duty
Pr. 70
Special regenerative brake duty
n1(Pr. 331)
Communication station number
Pr. 117
PU communication station number
n2(Pr. 332)
Communication speed
Pr. 118
PU communication speed
n3(Pr. 333)
Stop bit length
Pr. 119
PU communication stop bit length
n4(Pr. 334)
Parity check presence/absence
Pr. 120
PU communication parity check
n5(Pr. 335)
Number of communication retries
Pr. 121
Number of PU communication retries
n6(Pr. 336)
Communication check time interval
Pr. 122
PU communication check time interval
n7(Pr. 337)
Waiting time setting
Pr. 123
PU communication waiting time setting
n11(Pr. 341) CR/LF setting
Pr. 124
PU communication CR/LF selection
n16(Pr. 992) PU main display screen data selection
Pr.52
DU/PU main display data selection
n17(Pr. 993) Disconnected PU detection/PU setting lock Pr. 75
Reset selection/disconnected PU
detection/PU stop selection
Control terminal block
Screw type terminal block
Fix a wire with a flathead screw
(Screw size: M2(M3 for terminal A, B, C))
Length of recommended blade terminal: 6mm
Spring clamp terminal block
Fix a wire with a pressure of inside spring
Length of recommended blade terminal: 10mm
(Blade terminal of FR-S500 is unavailable)
PU
FR-PU04
FR-PU07
FR-PU04 (some functions, such as parameter copy, are
unavailable.)
Installation size
FR-D720-0.1K to 3.7K, FR-D740-0.4K to 3.7K, FR-D720S-0.1K to 1.5K, FR-D710W-0.1K to 0.75K are compatible in
mounting dimensions
Item
FR-S500
FR-D700
Содержание FR-D710W-0.1K
Страница 45: ...36 MEMO ...
Страница 61: ...52 MEMO ...
Страница 254: ...252 MEMO ...
Страница 296: ...294 MEMO ...
Страница 297: ...295 APPENDIX This chapter provides the APPENDIX of this product Always read the instructions before using the equipment ...
Страница 308: ...4 4 BCN C22005 652 MEMO bcnc22005652 fm 4 ページ 2013年12月26日 木曜日 午後12時58分 ...
Страница 312: ...4 4 BCN C22005 689 MEMO ...