239
Setting the parameter unit and operation panel
4.22.4 Magnitude of frequency change setting (Pr. 295)
The above parameter can be set when
Pr. 160 Extended function display selection
= "0".
The above parameter allows its setting to be changed during operation in any operation mode even if "0" (initial value) is set in
Pr. 77
Parameter write selection
.
(1) Basic operation
When a value other than "0" is set in
Pr. 295
, the minimum varying width when the set frequency is changed by the setting dial
can be set.
For example, when "1.00Hz" is set in
Pr. 295
, one click (one dial gauge) of the setting dial changes the frequency in
increments of 1.00Hz
→
2.00Hz
→
3.00Hz.
*One rotation of the setting dial equals to 24 clicks (24 dial gauges).
When setting the set frequency with the setting dial, frequency changes in 0.01Hz increments in the initial status.
Setting this parameter increases the magnitude of frequency which changes according to the rotated amount of the
setting dial, improving operability.
Parameter
Number
Name
Initial Value
Setting
Range
Description
295
Magnitude of frequency
change setting
0
0
Function invalid
0.01
The minimum varying width when the set
frequency is changed by the setting dial can
be set.
0.1
1
10
REMARKS
When machine speed display is selected with
Pr. 37
, the minimum increments of the magnitude of change is determined by
Pr.295
as well. Note that the setting value may differ as speed setting changes the set machine speed and converts it to the
speed display again.
When the set frequency (speed) is 100 or more, frequency is displayed in 0.1 increments. Therefore, the minimum varying
width is 0.1 even when
Pr. 295
<
0.1.
When the machine speed setting is 1000 or more, frequency is displayed in 1 increments. Therefore, the minimum varying
width is 1 even when
Pr. 295
<
1.
NOTE
For
Pr. 295
, unit is not displayed .
This parameter is valid only in the set frequency mode. When other frequency-related parameters are set, it is not
activated.
When 10 is set, frequency setting changes in 10Hz increments. Be cautions for the excess speed. (in potentiometer
mode)
When
Pr. 295
= "1"
1 click
1 click
1 click
Содержание FR-D710W-0.1K
Страница 45: ...36 MEMO ...
Страница 61: ...52 MEMO ...
Страница 254: ...252 MEMO ...
Страница 296: ...294 MEMO ...
Страница 297: ...295 APPENDIX This chapter provides the APPENDIX of this product Always read the instructions before using the equipment ...
Страница 308: ...4 4 BCN C22005 652 MEMO bcnc22005652 fm 4 ページ 2013年12月26日 木曜日 午後12時58分 ...
Страница 312: ...4 4 BCN C22005 689 MEMO ...