![Mitsubishi Electric FR-D710W-0.1K Скачать руководство пользователя страница 239](http://html.mh-extra.com/html/mitsubishi-electric/fr-d710w-0-1k/fr-d710w-0-1k_instruction-manual_239791239.webp)
237
Setting the parameter unit and operation panel
4.22.3 Operation panel frequency setting/key lock selection (Pr. 161)
The above parameter can be set when
Pr. 160 Extended function display selection
= "0".
(1) Using the setting dial like a potentiometer to set the frequency
The setting dial of the operation panel can be used for setting like a potentiometer.
The key operation of the operation panel can be disabled.
Parameter
Number
Name
Initial Value
Setting
Range
Description
161
Frequency setting/key lock
operation selection
0
0
Setting dial frequency
setting mode
Key lock invalid
1
Setting dial
potentiometer mode
10
Setting dial frequency
setting mode
Key lock valid
11
Setting dial
potentiometer mode
Operation example Changing the frequency from 0Hz to 60Hz during operation
Operation Display
1.
Screen at power-ON
The monitor display appears.
2.
Press
to choose the PU operation mode.
PU indicator is lit.
3.
Press
to choose the parameter setting
mode.
PRM indicator is lit.
(The parameter number read previously
appears.)
4.
Turn
until
(Pr. 160)
appears.
5.
Press
to read the present set value.
"
"(initial value) appears.
6.
Turn
to change it to the set value "
".
7.
Press
to set.
Flicker Parameter setting complete!!
8.
Change
Pr. 161
to the setting value of "
"
in the similar manner. (Refer to step 4 to 7.)
Flicker Parameter setting complete!!
9.
Mode/monitor check
Press
twice to choose the monitor/
frequency monitor.
10.
Press
to start the inverter.
11.
Turn
until "
" appears.
The flickering frequency is the set frequency.
You need not press
.
The frequency flickers for about 5s.
Содержание FR-D710W-0.1K
Страница 45: ...36 MEMO ...
Страница 61: ...52 MEMO ...
Страница 254: ...252 MEMO ...
Страница 296: ...294 MEMO ...
Страница 297: ...295 APPENDIX This chapter provides the APPENDIX of this product Always read the instructions before using the equipment ...
Страница 308: ...4 4 BCN C22005 652 MEMO bcnc22005652 fm 4 ページ 2013年12月26日 木曜日 午後12時58分 ...
Страница 312: ...4 4 BCN C22005 689 MEMO ...