268
Check first when you have a trouble
5.5.2
Motor or machine is making abnormal acoustic noise
Check
points
Possible Cause
Countermeasures
Refer
to
page
Input
signal
Disturbance due to EMI when frequency command is
given from analog input (terminal 2, 4).
Take countermeasures against EMI.
Parameter
Setting
Increase the
Pr. 74 Input filter time constant
if steady
operation cannot be performed due to EMI.
Parameter
Setting
No carrier frequency noises (metallic noises) are
generated.
In the initial setting,
Pr. 240 Soft-PWM operation selection
is
enabled to change motor noise to an unoffending
complex tone. Therefore, no carrier frequency noises
(metallic noises) are generated.
Set
Pr. 240
= "0" to disable this function.
Resonance occurs. (output frequency)
Set
Pr. 31 to Pr. 36 (Frequency jump)
.
When it is desired to avoid resonance attributable to the
natural frequency of a mechanical system, these
parameters allow resonant frequencies to be jumped.
Resonance occurs. (carrier frequency)
Change
Pr. 72 PWM frequency selection
setting.
Changing the PWM carrier frequency produces an effect
on avoiding the resonance frequency of a mechanical
system or a motor.
Auto tuning is not performed under General-purpose
magnetic flux vector control.
Perform offline auto tuning.
Gain adjustment during PID control is insufficient.
To stabilize the measured value, change the proportional
band (
Pr. 129
) to a larger value, the integral time (
Pr. 130
)
to a slightly longer time, and the differential time (
Pr. 134
)
to a slightly shorter time.
Check the calibration of set point and measured value.
Others
Mechanical looseness
Adjust machine/equipment so that there is no
mechanical looseness.
—
Motor
Operating with output phase loss
Check the motor wiring.
—
Contact the motor manufacturer.
Содержание FR-D710W-0.1K
Страница 45: ...36 MEMO ...
Страница 61: ...52 MEMO ...
Страница 254: ...252 MEMO ...
Страница 296: ...294 MEMO ...
Страница 297: ...295 APPENDIX This chapter provides the APPENDIX of this product Always read the instructions before using the equipment ...
Страница 308: ...4 4 BCN C22005 652 MEMO bcnc22005652 fm 4 ページ 2013年12月26日 木曜日 午後12時58分 ...
Страница 312: ...4 4 BCN C22005 689 MEMO ...